OutBack Power MATE Series Overview

CHARGE CONTROLLER
900-0131-01-00 Rev A.vsd\CC Setup on MATE\2012-03-21
©2012 OutBack Power Technologies. All Rights Reserved.
Page 8
Accessing the Advanced Menu:
Changing more detailed operating parameters
requires access to the Advanced Setup Menu.
Advanced Menu for the
FLEXmax Charge Controller
(Page 1 of 2)
ADV/CC/CHGR----------P02
output current 80.0 A
limit
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
MPPT mode
auto track
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
grid tie mode
nonGT
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
park MPP 77.0%
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
Mpp range limit %VOC
maximum 90%
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
rebulk voltage
24.8 Vdc
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
vbatt calibration
29.3 Vdc 0.0 Vdc
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
RTS compensation
wide
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
RTS comp limit
upper limit 28.2 Vdc
DOWN INC DEC PORT
ADV/CC/EQ------------P02
eq voltage 28.8 VOC
DOWN INC SETUP ADV
ADV/CC/EQ------------P02
eq time 1 hours
DOWN INC SETUP ADV
ADV/CC/EQ------------P02
end CC eq menu
TOP ADV MAIN
ADV/CC/EQ------------P02
eq auto eq interval
0 days
DOWN INC SETUP ADV
ADV/CC/AUX-----------P02
vent fan
DOWN INC SET PORT
ADV/CC/AUX-----------P02
aux control OFF
DOWN ON OFF PORT
ADV/CC/aux-----------P02
end of menu
TOP ADV MAIN
ADV/CC/CHRG----------P02
absorb voltage 28.8 V
DOWN INC DEC PORT
ADV/CC/CHRG----------P02
float voltage 27.2 V
DOWN INC DEC PORT
ADV/FX/CHRG----------P02
end charger menu
TOP ADV MAIN
ADV/CC/ADVANCED------P02
snooze mode
<0.6 AMP
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
wakeup mode
VOC change 3.0 V
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
wakeup mode
time 5 minutes
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
MPP range limit % VOC
minimum 1/2
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
absorb time
1.0 hours
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
absorb end amps
0A
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
RTS comp limit
lower limit 26.4 Vdc
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
auto restart
mode 0
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
AUX output polarity
active
DOWN INC DEC PORT
ADV/CC/ADVANCED------P02
Reset CC to factory
defaults?
DOWN YES NO PORT
ADV/CC/ADVANCED------P02
end CC advanced menu
TOP ADV MAIN
ADV/CC/PAGE1
choose category
ADV CHGR CCADV PG2
ADV/CC/PAGE2---------P02
choose category
PG1 EQ AUX MAIN
Advanced Menu for the
FLEXmax Charge Controller
(Page 2 of 2)
MAIN--------------------
3:02:14P
SUM STATUS SETUP ADV
A
1. Press the <INC> soft key
until “141” is displayed on
the LCD.
2. Press the <ENTER> soft key
to accept the password and
move forward to the Device
Selection Menu.
B
B
ADV/PASSOWRD------------
Enter the password
141
ENTER INC DEC EXIT
ADV/PASSWORD------------
Enter the password
132
ENTER INC DEC EXIT
A
ADV/SETTINGS/WARNING
changes made could
adversely affect
system performance
MAIN--------------------
3:02:14P
SUM STATUS SETUP ADV
ADV--------------------
choose device
FX CC DC MATE
To return to the Main
screen at any time:
MAIN-------------------
3:02:14P
SUM STATUS SETUP ADV
Press and hold the 2 left
soft keys at the same time.
Release when the Main
screen appears.