Outback Power Specification Sheet

OutBack Power reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 2019 OutBack Power. All Rights Reserved. OutBack Power is a registered trademark of Alpha Technologies Services, Inc.
2
Radian E-Series Specifications 08/2019
www.outbackpower.com
#980-00077-01-001 REV A
Models:
GS7048E GS3548E
Instantaneous Power (100ms)
16300VA 8200VA
Surge Power (5 sec)
11500VA 5800VA
Peak Power (30 min)
7900VA 4000VA
Continuous Power Rating (@ 25°C)
7000VA 3500VA
Nominal DC Input Voltage
48VDC 48VDC
AC Output Voltage (selectable)
230VAC (210 to 250VAC) 230VAC (210 to 250VAC)
AC Output Frequency (selectable)
50Hz (60Hz) 50Hz (60Hz)
Continuous AC Output Current (@ 25°C)
30AAC 15.2AAC
Idle Power
Invert mode, no load: 34W Search: 10W Invert mode, no load: 34W Search: 10W
Typical Efficiency
92% 92%
Peak Efficiency
96% 96%
Total Harmonic Distortion
Typical: <2% Maximum: <5% Typical: <2% Maximum: <5%
Output Voltage Regulation
±2% ±2%
AC Input Voltage Range (MATE3s Adjustable)
L-N: 170 to 290VAC L-N: 170 to 290VAC
AC Input Frequency Range
50Hz: 45 to 55Hz 60Hz: 54 to 66Hz 50Hz: 45 to 55Hz 60Hz: 54 to 66Hz
Grid-Interactive Voltage Range
L-N: 208 to 252VAC L-N: 208 to 252VAC
Grid-Interactive Frequency Range
50Hz: 47 to 51Hz 60Hz: 57 to 61Hz 50Hz: 47 to 51Hz 60Hz: 57 to 61Hz
Maximum AC Input Current
50AAC 50AAC
Maximum Utility Interactive Current
30A 15A
Continuous Battery Charge Output
100ADC 50ADC
Advanced Battery Charging
Flooded, gel, AGM, lithium-ion and flow chemistry Flooded, gel, AGM, lithium-ion and flow chemistry
DC Input Voltage Range
40 to 64VDC 40 to 64VDC
Accessory Ports
Remote temperature sensor (included), MATE3s and HUB communications Remote temperature sensor (included), MATE3s and HUB communications
Warranty
Standard 5 year, extended 10 year available Standard 5 year, extended 10 year available
Weight (lb/kg)
Unit: 125 / 56.7 Shipping: 140 / 63.5 Unit: 82 / 37.2 Shipping: 94 / 42.6
Dimensions H × W × D (in/cm)
Unit: 28 × 16 × 8.7 / 71.1 × 40.6 × 22.1 Shipping: 34.5 × 21 × 14.5 / 87.6 × 53.3 × 36.8 Unit: 28 × 16 × 8.7 / 71.1 × 40.6 × 22.1 Shipping: 34.5 × 21 × 14.5 / 87.6 × 53.3 × 36.8
Temperature Range
Rated: –20 to 50°C Maximum: –40 to 60°C Rated: –20 to 50°C Maximum: –40 to 60°C
Listings/Certifications
IEC 62477-1, AS4777.2, AS477.3, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS3100, CE, RoHS
compliant per directive 2011/65/EU
IEC 62477-1, AS4777.2, AS477.3, EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3, AS3100, CE, RoHS
compliant per directive 2011/65/EU
7.0kVA 7.0kW 7.0kVA
5.95kW
Power Rating Notes
Inverters that specify power in VA but do not use the unity standard Power Factor
(PF) could have misleading power specifications. Volt-amps (VA) is a total inverter
output, while watts (W) represent the power consumed by the electrical loads.
PF, which varies by types of loads, is the ratio of W to VA, and the difference
between the two is power in the circuit that does no useful work. At 1.0PF
(unity), all power is used. This is the industry standard used by OutBack Power.
Radian GS7048E Power Factor Chart
Power Factor
1.0
0.75
0.5
0.25
0.0
Industry-Standard Non-Industry Standard
Radian GS7048E Power Rating Chart
Power (VA)
20000
15000
10000
5000
0
100ms 5 sec 30 min continuous
Instantaneous Power Rating
Most stringent, massive load start GS7048E: 16300VA
Surge Power Rating
Less stringent load start GS7048E: 11500VA
Peak Power Rating
Frequent “heavy duty” load requirements GS7048E: 7900VA
Continuous Power Rating
Sustained “real world” load requirements GS7048E: 7000VA
16300VA
11500VA
7900VA
7000VA
Peak Efficiency Rating
Highest efficiency rating achievable GS7048E: 96%
Typical Efficiency Rating
Real world efficiency with variable loads GS7048E: 92%
Radian GS7048E Efficiency Rating Chart
Efficiency
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
2kVA 4kVA 6kVA 8kVA
96% (PEAK)92% (TYPICAL)