User Guide
Troubleshooting
900-0112-01-00 Rev B  33 
Table 4  Basic Troubleshooting Steps 
Symptom  Unusual LEDs  Possible Cause  Possible Remedy 
None (AC IN LED is 
illuminated) 
Inverter priority 
MATE system display only: Check 
Stop Sell 
Reasons
 screen 
(STATUS/FX/SELL)
. The 
inverter may be behaving correctly. 
MATE3 system display only: Check 
Sell Status
screen with 
Grid Status
 soft key. The 
inverter may be behaving correctly. 
None (AC IN LED is 
illuminated) 
AC source does not meet 
requirements. 
Verify grid voltage and frequency. 
Determine if they are within the inverter’s 
approved limits. If not, the inverter is 
behaving correctly. Contact the utility 
company if necessary. 
MATE and MATE3 system display: The 
program selections for limits are 
IEEE
 or 
USER
.  
None (AC IN LED and 
Inverter are 
illuminated) 
High output loads will consume 
power before it is returned to 
the utility grid. 
Turn off some output loads and observe the 
sell function. 
None (AC IN LED is 
illuminated) 
Inverter has been set to accept a 
generator. 
Inverter will not intentionally sell to a 
generator. 
MATE system display only: Set
 ac transfer 
control
 to 
grid. 
MATE3 system display only: Set
 Input Type
to 
Grid
 in the 
AC Input and Current Limit
menu. 
Will not sell 
power to the 
utility grid. 
None (AC IN LED is 
illuminated) 
Sell function has been disabled. 
MATE system display only: Set 
grid tie 
authority
 to 
GridTied (ADV/FX/SELL)
MATE3 system display only: Set 
Grid-Tie 
Enable 
to 
Y.
AC IN LED off  No AC input.  Check the AC voltage on the inverter’s input 
terminals. If not present, the problem is 
external. If present, the inverter could be 
damaged. Contact OutBack Technical 
Support (see inside front cover of this 
manual). 
Will not 
connect to the 
AC source. 
(Continued on 
next page) 
AC IN LED flashes  Inverter set to disconnect 
from AC. 
MATE system display only: Change the 
AC 
Input Control 
setting from 
DROP
 to 
USE
with the 
AC IN
 hot key. 
MATE3 system display only:  Change the 
AC 
Input Mode 
setting from 
DROP
 to 
USE
 with 
the 
AC INPUT
hot key. 
(If this setting was intentional, then no 