Outback FXR/VFXR Renewable Series

2
OutBack Power Technologies, Inc. 1628 W Williams Drive, Phoenix, AZ 85027
Tel: +1 360 435 6030 Technical Support: +1 360 618 4363 Email: sales@outbackpower.com
For more information visit www.outbackpower.com
© 2020 OutBack Power Technologies, Inc. All Rights Reserved. Trademarks and logos are the property of Alpha Technologies Services, Inc.,
EnerSys and its affiliates unless otherwise noted. Subject to revisions without prior notice. E. & O.E.
FXR/VFXR A-Series Specifications
Models:
Sealed Vented
FXR2012A FXR2524A FXR3048A VFXR2812A VFXR3524A VFXR3648A
Instantaneous Power (100ms)
4800VA 6000VA 6000VA 4800VA 6000VA 6000VA
Surge Power (5 sec)
4500VA 5400VA 5400VA 4500VA 5400VA 5400VA
Peak Power (30 min)
2500VA 3200VA 3200VA 3200VA 4000VA 4000VA
Continuous Power Rating (@ 25°C)
2000VA 2500VA 3000VA 2800VA 3500VA 3600VA
Nominal DC Input Voltage
12VDC 24VDC 48VDC 12VDC 24VDC 48VDC
AC Output Voltage (Selectable)
120VAC (100 to 130VAC) 120VAC (100 to 130VAC) 120VAC (100 to 130VAC) 120VAC (100 to 130VAC) 120VAC (100 to 130VAC) 120VAC (100 to 130VAC)
AC Output Frequency (Selectable)
60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz) 60Hz (50Hz)
Continuous AC Output Current (@ 25°C)
16.7AAC 20.8AAC 25AAC 23.3AAC 29.2AAC 30AAC
Idle Power
Full: ≈34W Search: ≈9W Off: ≈3W Full: ≈34W Search: ≈9W Off: ≈3W
Typical Efficiency
90% 92% 93% 90% 92% 93%
CEC Weighted Efficiency
Not applicable Not applicable 91% Not applicable 90.5% 91%
Total Harmonic Distortion
Typical: <2% Maximum: <5% Typical: <2% Maximum: <5%
Output Voltage Regulation
±2.5% ±2.5% ±2.5% ±2.5% ±2.5% ±2.5%
AC Input Voltage Range (MATE3s Adjustable)
85 to 140VAC 85 to 140VAC 85 to 140VAC 85 to 140VAC 85 to 140VAC 85 to 140VAC
AC Input Frequency Range
54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz) 54 to 66Hz (45 to 55Hz)
Grid-Interactive Voltage Range
106 to 132VAC 106 to 132VAC 106 to 132VAC 106 to 132VAC
Grid-Interactive Frequency Range
59.3 to 60.5Hz 59.3 to 60.5Hz 59.3 to 60.5Hz 59.3 to 60.5Hz
Maximum AC Input Current
60AAC 60AAC 60AAC 60AAC 60AAC 60AAC
Continuous Battery Charge Output
100ADC 55ADC 35ADC 125ADC 82ADC 45ADC
Maximum Battery Charging
AC: 14AAC DC: 100ADC
Power: 1360VA
AC: 14AAC DC: 55ADC
Power: 1500VA
AC: 14AAC DC: 35ADC
Power: 1900VA
AC:18AAC DC: 125ADC
Power: 1700VA
AC: 20AAC DC: 82ADC
Power: 2230VA
AC: 60AAC DC: 45ADC
Power: 2450VA
Advanced Battery Charging
Flooded, gel, AGM, lithium-ion and flow chemistry Flooded, gel, AGM, lithium-ion and flow chemistry
DC Input Voltage Range
10.5 to 17VDC 21 to 34VDC 42 to 68VDC 10.5 to 17VDC 21 to 34VDC 42 to 68VDC
Accessory Ports
Remote temperature sensor (included), MATE3s and HUB communications Remote temperature sensor (included), MATE3s and HUB communications
Warranty
Standard 5 year, extended 10 year available Standard 5 year, extended 10 year available
Weight (lb/kg)
Unit: 62 / 29 Shipping: 67 / 30 Unit: 61 / 28 Shipping: 67 / 30
Dimensions H × W × L (in/cm)
Unit: 13 × 8.25 × 16.25 / 21.75 × 13 × 22 Shipping: 21.75 × 13 × 22 / 55 × 33 × 56 Unit: 13 × 8.25 × 16.25 / 21.75 × 13 × 22 Shipping: 21.75 × 13 × 22 / 55 × 33 × 56
Temperature Range
Rated: −20 to 50°C Operating: −40 to 60°C Storage: −40 to 60°C Rated: –20 to 50°C Operating: −40 to 60°C Storage: −40 to 60°C
Relative Humidity Rating
93% 93% 93% 93% 93% 93%
Auto-Transfer Switch
UL 1741 testing demonstrates grid-safe operation and inverter is capable of islanding with built-in ATS
functionality included internally
UL 1741 testing demonstrates grid-safe operation and inverter is capable of islanding with built-in ATS
functionality included internally
Listings/Certifications
UL1741, CSA C22.2 No. 107.1, UL1778, Annex FF UL1741, CSA C22.2 No. 107.1, UL1778, Annex FF
RoHS Compliant
Yes Yes Yes Yes Yes Yes