teur peut présenter des risques de brûlures pour la peau. Dans ces conditions, il est important
d’éviter tout contact avec la partie supérieure, la base ou le dissipateur thermique du capteur.
Le capteur ne doit pas être utilisé à une température ambiante supérieure à 50˚C. 50˚C est la
température maximale certifiée d’opération sûre du capteur.
Equipment Label: Includes model and serial number and a notice that states the unit is a Class 1 Laser
Product, is affixed to the underside of the Sensor Enclosure Base. It is only visible after the attached
mount with which the Sensor is shipped, is removed. For location details please refer to figure
Sensor
Components
in the Mechanical Interface Section.
L’étiquette de l’équipement, comprenant le modèle, le numéro de série, et la classification du produit
laser (ici, classe 1), est apposée au-dessous de la base du boîtier du capteur. Il n’est visible qu’après
avoir retiré le diffuseur de chaleur avec lequel le capteur est expédié. L’emplacement est décrit avec
précision dans la section
Sensor Components.
Electromagnetic Compatibility: The OS2 is an FCC 47 CfR 15 Subpart B device. This device complies
with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
“Ouster” and “OS2” are both registered trademarks of Ouster, Inc. They may not be used without
express permission from Ouster, Inc.
If you have any questions about the above points, contact us at
legal@ouster.io.
1.2 Proper Assembly, Maintenance and Safe Use
The OS2 can be easily set up by following the instructions outlined in Mounting Guidelines. Any mount-
ing orientation is acceptable. Each sensor is shipped with an attached mount that can be used for test
or normal use within the specified operating conditions. The sensor may also be affixed to any other
user specific mount of appropriate thermal capacity. Please contact Ouster for assistance with ap-
proving the use of user specific mounting arrangements.
Any attempt to utilize the sensor outside the environmental parameters delineated in the OS2
datasheet may result in voiding of the warranty.
When power is applied, the sensor powers up and commences boot-up with the laser disabled. The
boot-up sequence is approximately 60s in duration, after which the internal sensor optics subassem-
bly commences spinning, the laser is activated, and the unit operates in the default 1024 x 10 Hz mode.
When the sensor is running, and the laser is operating, a faint red flickering light may be seen behind
the optical window.
Note that the OS2 utilizes an 865nm infrared laser that is only dimly discernible to the naked eye. The
sensor is fully Class 1 eye safe, though Ouster strongly recommends against peering into the optical
window at close range while the sensor is operating. Ouster sensors are equipped with a multi-layer
series of internal safety interlocks to ensure compliance to Class 1 Laser Eye Safe limits.
The OS2 is a hermetically sealed unit, and is not user-serviceable. Any attempt to unseal the enclosure
has the potential to expose the operator to hazardous laser radiation.
The sensor user interface may be used to configure the sensor to a number of combinations of scan