User Manual

Selecting a Power Supply Cord/Cordset
If purchasing a power supply locally, it should be supplied with an appropriate power supply cord or
cordset for use with the power supply. If it’s necessary to select a power supply cordset for the Ouster
supplied power supply, it should be safety certified by a test house acceptable to the local region of
use, supplied with an IEC 60320, Type C6 cord connector to mate with the power supply and a plug
for connection to an AC outlet with an earthing contact/pin.
Environmental Ratings
All Interface Boxes are suitable for use indoors only in clean, protected environments at temperatures
between -20 °C and +50 °C. Interface Boxes are not designed for use outdoors or in environments
that are not protected from dust, moisture, or high humidity.
Mounting
The interface box may be mounted on a table top or on a wall (or similar vertical surface) not higher
than 2 m above the floor. Use not less than two (2) screws (M4 SHCS 10mm or longer are recom-
mended) to secure the interface box to the mounting surface.
Figure7.7: Mounting Guidelines -Ibox
For additional OS2 sensor CAD files refer to
Lidar Product Details page.
25