7.1 Cables
Cable Types
3 types of cables are compatible with the OS2 sensors. Their physical characteristics are presented
in the table
Cable Characteristics.
The cable and plug are an element of the sensor ingress protection. Without this, the ingress protec-
tion rating may be compromised. Bending the cable at a sharp angle directly after egress from the
plug over mold should also be avoided. Sharp bends and high axial stresses on the cable immediately
adjacent to the plug over mold may create a moisture ingress path into the connection. Please note
the cable minimum bend radius requirements.
Note: We no longer offer Type 1 cables for sale. Please contact your Ouster sales representative for
questions regarding available cable lengths, connector types, and termination options.
Table 7.1: Cable Characteristics
Cable Outer Diame-
ter
Cable Minimum Bend
(Static)
Cable Minimum Bend (Flexi-
ble)
Type 1
(Thick)
10.5mm 79mm 158mm
Type 2 (Thin) 8mm 40mm 80mm
Type 3 8.2mm 41mm 82mm
Note: Type 3 Cable has an imprint that states “Type 3” on it whereas, Type 2 does not have any
identifiers.
Note: Ouster recommends using a right angled connector cable for use cases wherein the cable
needs to be bent within the first 5 cm between the connector and the rest of the cable.