Instruction Manual

Conguration of parameters
The options will be presented in the following order:
°C °F
Temperature display
°C or °F
Economy mode (Green)
The economy mode can be set between -0.5°C to -5°C.
E.g.: By setting this parameter to -3°C, when this mode is
selected the setpoint of the device will decrease by 3°C.
Freeze protect mode (Blue)
The freeze protect mode can be set between 5°C to 10°C (41°F to
50°F).
E.g.: By setting this parameter to 7°C (45°F), when this mode is
selected the setpoint of the device will be at 7°C (45°F).
Ambient temperature oset
The device’s thermostat is calibrated in the laboratory to an
accuracy of ± 0.5°. However, depending on the conditions in
which it is installed, the actual ambient temperature in the room
may be dierent from the one displayed. In order for the room
temperature to be exactly as displayed, you must use the room
temperature oset function.
Locking
This feature eliminates unwanted temperature adjustments and
the use of dierent thermostat modes. Before activating it, make
sure you have set your set temperature correctly.
ON Light On at all times (buttons and screen)
AUTO
Light of buttons and the display turn O 5 seconds after
use.
Brightness
Light intensity of the screen on a scale of 1 to 5.
Temperature display
The thermostat displays the measured room temperature by default.
The heating intensity will be indicated by an intensity indicator.
The fan intensity will be indicated by a fan intensity indicator on the display.
To display the set temperature, press once for 1 second on one of the adjustment
buttons or . The set temperature appears for 5 seconds.
To change the set temperature, press once for 1 second on one of the adjustment
button or , when the set temperature is displayed, press the adjustment button
repeatedly until the desired temperature is displayed.
Conguration menu
To congure the thermostat parameters, access the conguration menu by following
the steps below:
Press the buttons
and simultaneously for 3 seconds until the display ashes
and release. The buttons will be yellow.
Use the adjustment buttons or to adjust the displayed parameter.
To go to the next conguration; press the buttons
and simultaneously and
release immediately.
In order to exit the conguration menu at any time and access the display,
simultaneously press the buttons
and for 3 seconds or wait
5 seconds and the thermostat will exit the menu.
Note: The thermostat will automatically record any changes.
Standby
The stanby desactivates all the fonctions of the heater. It is suggested when heating is
not needed for example, during the summer.
To put the heater on stanby, press the button
4 seconds. During this sequence, the
display will show a countdown from 4 seconds to 1. Then after, the display will show
« OFF » before shutdown.
To power on the heater, press the button
3 seconds. The unit will operate in the last
operating mode stored in memory before the standby.
Calibration sequence / Power outage
When connecting or after a power outage, the heater will start with a calibration
sequence. During the calibration, the display will show a countdown of 60 seconds,
the 4 buttons will ash in cyan, and the display will show the letters “CAL” for
calibration. The fan will be at full power during calibration and all buttons will be
deactivated for user.
When the calibration time is up, the room temperature will be shown and the last
mode in memory before the power outage will be activated.
If the calibration doesn’t work, the error code E9 appears on the display. To remove
the error code press the button
3 seconds.
The heater will automatically restart the calibration sequence. If another error code
appears on the display, contact technical support.