Instruction Manual

Technical specications
Voltage, frequency: 120/240-208V, 50/60 Hz
Maximum load (resistive only): 12.5A
Maximum load (inductive only): 0.38A
Adjustment range: 5°C to 30°C (41°F to 86°F)
Resolution: 0.5°C (1°F)
Operating mode
Comfort, economy, freeze protect, Boost.
Button color meaning
White: Comfort mode
Yellow: Conguration menu
Green: Economy mode
Blue: Freeze protect mode
Red: Thermostat in error
Purple: Boost mode
Cyan: Calibration
Features
- Calibration sequence
- Display in °C or °F.
- Button lock.
- Light of buttons and screen: ON or AUTO.
- Adjust the light brightness of the screen, scale from 1 to 5.
- Adjust ambient temperature oset.
- Setting the freeze protect mode 5°C to 10°C (41°F to 50°F) in the
conguration menu.
- Setting the economy mode in the conguration menu.
- Return to the last mode in memory in case of a power outage.
Error codes
E1: Temperature probe disconnected.
Red LED ashes: Indicates a risk of overheating.
E6: Over tempreature: Red LED ashed quickly. No heating when the
device is over temperature.
E9: Calibration problem.
Default setup
Economy mode: Lowers the setpoint temperature by -3°C
Freeze protect mode: Sets the temperature at 10°C (50°F)
Comfort mode: Temperature set at 21°C (70°F)
Light of the buttons and the screen: ON
Screen brightness, set at 3
Navigation
Main Menu
Increase the temperature Press 1-second
Adjustment button
Decrease the temperature Press 1-second
Adjustment button
Change mode Press 1-second
Adjustment buttons
▲ ▼
Reset Press 15-second
Adjustment buttons
▲ ▼
Activate Boost mode Press 1-second
Hourglass button
Standby Press 4-second
Power On button
/Standby
Power on Press 3-second
Power On button
/Standby
Conguration Menu
Enter menu Press 3-second
Buttons
+
Change menu Press 1-second
Buttons
+
Increase or change value Press 1-second
Adjustment button
Decrease or change value Press 1-second
Adjustment button
Exit menu Press 3-second
Buttons
+
OPERATING
INSTRUCTIONS
OF THE THERMOSTAT
Power On
button/
Standby
Hourglass
button
Brightness
adjustment
°C or °F
adjustment
Menu
offset
adjustment
Locking
Adjustment
button
Comfort
mode
Economy
mode
Freeze protect
mode
Heating
intensity
Fan
intensity
Adjustment
button
Operating modes
To change the operating mode,
simultaneously press the 2 adjustment buttons
and ▼ for 1 second.
The thermostat oers three operating modes. The icon of the operating mode
in application appears in the lower right corner of the screen.
Comfort mode (White):
Preferred mode when heating is necessary.
E.g.: You are at home and want heating suitable for your
comfort. Adjustment between 10°C to 30°C (50°F to 86°F).
Economy mode (Green):
Mode to privilege in the moments requiring less heating.
The set temperature is lowered according to the possible
adjustment economy mode between -0.5°C and -5°C.
E.g.: When you sleep or when you are not at home during the
day, this mode saves energy during this time.
Freeze protect mode (Blue):
Mode to favor when very little heating is necessary.
E.g.: You spend a week outside the house and heating of only
5°C to 10°C (41°F to 50°F) is sucient during your absence.
Boost mode (Purple)
Suggested mode when a fast heating is needed in a room for example when a
warm room is needed at the end of a shower.
To activate this mode, press the hourglass button
1 second. The display
will ash and will indicate the boost time. When the display is ashing, the
number of minutes can increase by 5 minutes by pressing the hourglass button
again. When the display stop ashing, the number of minutes remaining is
shown before the end of this mode.
At any time, the boost time can be increased or decreased by 1 minute by
pressing
or ▼ or increase by 5 minutes by pressing the hourglass button
.
The boost mode will stop when the boost time is up or by pressing the
hourglass button
3 seconds.