Instruction Manual
CAUTION:
Hightemperature,riskofre,keepelectricalcords,drapery,furnishings,andothercombustiblesat
least36in.(915mm)fromthefrontoftheheaterandawayfromthesidesandtop.
WARNING:
To reducetheriskofre,donotstoreorusegasolineorotherammablevaporsandliquidsinthe
vicinity of the heater.
1. Usethetemplateprovidedwiththeheater.
a) Recesswallmounting
- Provide a minimum opening of 2 5/8 in. (67 mm) deep. HOLE MUST BE CUT PRECISELY.
- Usethetemplateprovidedtocutthewallopening.Thebottomoftheunitmustbeat
least 6in.(152mm)fromtheoorand2in.(51mm)fromtheadjacentwalls.
Recommended installation height is 12 in. (305 mm) from the bottom of the unit for a better
temperature regulation.
b) Surfacewallmounting
- Thebottomoftheunitmustbeatleast6in.(152mm)fromtheoorand2in.(51mm)from
theadjacentwalls.Recommendedinstallationheightis12in.(305mm)fromthebottomof
the unit for a better temperature regulation.
- Locatepositionningofthesupplywireandmakea1in.(25mm)diameterhole.Firmly
installthe3screwssuppliedtothewall.DONOTOVERTIGHTSINCEYOUWILLNEED
TO SLIDE THE HEATER AT STEP 6.b).
2. Removethefrontcoverbyunscrewingthescrewintheairoutlet(atthebottom)
andbyslidingthefrontcoverupwards.
3. Disconnectthethermostatfromthecasingbypullingthewhiteplasticconnector
(modelwithbuilt-inthermostat)andputthefrontcoveronacleansurface.
4. Remove the connection box cover. Remove the appropriate knock-out
from the box for the electrical supply.
5. Wiretheheateraccordingtonationalandlocalcodesandasperthewiringdiagrambelow.
6. Installation:
a) Recessedwallmounting
Installthecasinginthewallopeningusingtheholeslocatedonthe edge on each side
of the recess box.
b) Surfacewallmounting
Aligntheoversizedpartoftheholeswiththescrewsalreadyonthewall,
thenslidetheheaterdownward.Makesurethatthe3screwsarewellsupported
atthetopofthekeyhole(smallpart).Oncetheheaterinplace,nishtightening
the3screws.
7. Reconnectthethermostattothecasingbyclipingbothpartsofthewhiteplasticconnector
together.Replacetheatcableinthewireclip.
8. Put the connection box cover back.
9. Reinstall the front cover by inserting the 2 tabs located at the top of the front cover into the
2slotslocatedatthetopofthecasing,thentightenthescrewlocatedintheairoutlet.
Important: make sure the front cover is properly seated and secure to the casing.
10. Test the heater.
(Themodelwithbuilt-inthermostatstartswithacalibrationsequence).
a) Adjust heater thermostat at maximum setting. It is possible that a slight heating smell emerges
fromtheopenings,whichistotallynormalandwillstopafterafewminutesofoperation.
b) Adjust thermostat at minimum setting.
INSTALLATION
INS
TRUCTIONS
RECESSED OU SURFACE MOUNTING STEPS
Load / Line 2
L1
Load 1
L2/N
Load 2
Fan L
Fan H
MMMM
T1
T2
L1
L2/N
L1
L2/N
Power base
GND
Load / Line 2
750W
750W
Element
LO
HI
Model with
built-in thermostat
Thermal
fuse
Hi-limit
Disconnect
optional
Model without built-in thermostat
750W
750W
GND
MMM
LO
M
HI
1500W
750W
L1
L2/N
T1
T2
L1
L2/N
Power selector
Thermal
fuse
Element
Hi-limit
Disconnect
optional
371 mm
14 5/8"
275 mm
10 13/16"
Dimension of
thewallopening
Depth of
thewallopening
51 mm (2’’)
minimum
Template provided
withtheheater
2’’
minimun
51 mm
2’’
minimun
51 mm
305 mm (12’’) recommended
152 mm (6’’) minimum
KOE Ø7/8"
22mm
KOE Ø7/8"
22mm
Distance minimum du sol 6"; suggérée 12"
6" minimum clearance from floor; 12" suggested
KOE Ø1/4"
6.4mm
Note importante :
Important note :
Contour du devant
Front cover outline
Si vous avez à imprimer ce document à partir du fichier en PDF,
veuillez vous assurez que les proportions sont respectées
en vous référant aux dimensions inscrites
If you print this document from the PDF file,
please make sure you have the right dimensions
by refering to the written dimensions.
INS625-202205-00
275mm
( 10 13/16" )
371mm
( 14 5/8" )
GABARIT DE DÉCOUPE / CUTOUT TEMPLATE
(INSTALLATION ENCASTRÉE) / (RECESSED INSTALLATION)
216mm
( 8 1/2" )
56.9mm
( 2 1/4" )
78.9mm
( 3 1/8" )
88.9mm
( 3 1/2" )
21mm
( 13/16" )
333.7mm
( 13 1/8" )
30mm
( 1 3/16" )
72mm
( 2 13/16" )
88mm
( 3 7/16" )
103mm
( 4 1/16" )
White plastic