Instruction Manual

5
Warnings
These are vitally important safety warnings that must be followed. Failure to do so could cause
overheating and result in serious fire hazard or electrical shock)
Improper installation use and/or maintenance of electrical heating cable can cause fire, electric shock
and/or freezing of pipe.
Make sure there is a properly grounded electrical outlet close enough to plug in the cable.
Heating cables must be installed in compliance with the (U.S.) National Electrical Code and
Canadian Electrical Code. Ground fault protection (GFCI) of the power supply circuit is required.
Proper installations are based on the use of manufacturer’s specified parts only. Any substitute parts
or vinyl electrical tapes should not be used.
Do not connect power to the heating cable while it is coiled.
Do not install damaged heating cable.
Minimum pipe length is 0.9 m (3 ft.)
Never alter the cable in any way. If made shorter, it will overheat. Once cut, the cable cannot be
repaired.
Do not install cable on more than one pipe.
Never allow the heating cable to touch, cross or overlap itself at any point.
Disconnect the cable from its power source during installation.
Always keep the heating section of the system at least 2.5cm (1in) away from combustible surfaces.
Caution
Do not install the electric heating cable system when the ambient temperature is colder than the
minimum installation temperature 0°C (32°F).
These instructions must be saved and made available to the owner and transferred to future owners.
If after reading the following instructions, you still have questions regarding installation or operation
of this heating cable, contact: Technical Support.