Users Manual

PRODUCT INFORMATION
Pull-force measurement system
3 OPERATION
The POWER-CHECK is a precision instrument Please handle with care!
Spindle rotation with the measuring device is not allowed!
Measuring conditions: the following requirements must definitely be fulfilled in order to
get accurate measurements
observe measuring range: VARIATIONS # 2.5 // 8
temperature range: +15 °C to + 35 °C
It is possible to use the measuring device in a tool magazine.
As soon as the measuring device is embedded in the tool holder and the threshold value is overstepped,
the device switched into the sending mode.
threshold value: = min.-value of the measuring range VARIATIONS # 2.5 // 8
Time sequence: recording and sending
short clamping process long clamping process repetitions of short clamping
processes
95100422PE_2020-09-22
Subject to modification due to technical advance! // 12
F
S
W
t
5 5
F
S
W
1
W
2
t
5 5
F
S
W
t
5 5
record the measured value W
send the measured value W
S = threshold value
[sec]