User's Manual

CHAPTER3
Usingterminalcommands
49
EXAMPLE # 441 XDATA 0 8 0 255 1 0
441 XDATA 0 199 0x18 0x4A4211BC 1 0 0xF6 :8F0384645739
0
#
XIMME
A
VAILABLE FOR RA440
DESCRIPTION Samples all inputs and immediately returns the sampled data.
PARAMETERS First parameter specifies the sample mode, which has to be 2 for raw
data. The second parameter sets the maximum packet size. If you
specify the third parameter, you can select a specific input connector.
Note: Only sample mode 2 is supported on the RA440.
REMARKS GET only. The command needs a specific delay to execute. The delay
depends on the setting at the SST command.
RETURNS A data block of logical channel, raw adc and counter values.
ID XIMME
int_chnl int_dig bat temp ext_volt 0
{chnl_nr dig_byte raw_cabl1 raw_cabl2 raw_cabl3 cnt}
The format of the above response is as following:
int_chnl is the logical channel number of the internal connector
(always 0).
int_byte is a byte (0 to 255) and shows whether the SOLAR CELL
is connected and if the charger is activated.
bat is the measured battery value (for details see the INFO
command).
temp is the measured temperature value (for details see the
INFO command).
ext_volt is the external DC INPUT level using the following
conversion:
chnl_nr is the logical channel of the shown connector:
1 — IO-A
2 — IO-B
3 — IO-C
4 — IO-D
The RA440 has no external sensor connectors. Therefore the values of
the two batteries are shown on raw_cabl1 of IO-A and IO-B.
dig_byte is the digital status byte.
raw_cabl1 is the raw value read on cabling 1 by the analog-digital
converter.
DCInput
Volts>@
ext_volt
255
-------------------
27.5u=