User's Manual
CHAPTER3
Usingterminalcommands
49
EXAMPLE # 441 XDATA 0 8 0 255 1 0
441 XDATA 0 199 0x18 0x4A4211BC 1 0 0xF6 :8F0384645739
0
#
XIMME
A
VAILABLE FOR RA440
DESCRIPTION Samples all inputs and immediately returns the sampled data.
PARAMETERS First parameter specifies the sample mode, which has to be 2 for raw
data. The second parameter sets the maximum packet size. If you
specify the third parameter, you can select a specific input connector.
Note: Only sample mode 2 is supported on the RA440.
REMARKS GET only. The command needs a specific delay to execute. The delay
depends on the setting at the SST command.
RETURNS A data block of logical channel, raw adc and counter values.
ID XIMME
int_chnl int_dig bat temp ext_volt 0
{chnl_nr dig_byte raw_cabl1 raw_cabl2 raw_cabl3 cnt}
The format of the above response is as following:
• int_chnl is the logical channel number of the internal connector
(always 0).
• int_byte is a byte (0 to 255) and shows whether the SOLAR CELL
is connected and if the charger is activated.
• bat is the measured battery value (for details see the INFO
command).
• temp is the measured temperature value (for details see the
INFO command).
• ext_volt is the external DC INPUT level using the following
conversion:
• chnl_nr is the logical channel of the shown connector:
• 1 — IO-A
• 2 — IO-B
• 3 — IO-C
• 4 — IO-D
The RA440 has no external sensor connectors. Therefore the values of
the two batteries are shown on raw_cabl1 of IO-A and IO-B.
• dig_byte is the digital status byte.
• raw_cabl1 is the raw value read on cabling 1 by the analog-digital
converter.
DCInput
Volts>@
ext_volt
255
-------------------
27.5u=