User's Manual

CHAPTER3
Usingterminalcommands
45
RETURNS The lower (switch on) and the higher limit (switch odd), both in volts x
10.
REMOTE Yes, SET only.
EXAMPLE # PMP 65 72
441 PMP 0
#
# PMP
441 PMP 65 72 0
#
ROUTE
A
VAILABLE FOR A440
DESCRIPTION Sets/returns the routing information of a device.
PARAMETERS None, or a route (with destination) containing up to eight
intermediaries. When only the destination ID is given, the route for
this device is deleted.
REMARKS GET/SET.
RETURNS The command’s success or error code and the route table.
REMOTE Yes, but only to an A440 attached to an RA440.
EXAMPLE For MFS:
# ROUTE 445 43
442 ROUTE 0
#
# ROUTE
442 ROUTE 445 43 0
#
RSSI
A
VAILABLE FOR A440
DESCRIPTION Sets/returns the Relative Signal Strength Indicator threshold at which
the RF receiver must wake up.
PARAMETERS The threshold value. For the A440, it can take values from 0 to 255; it
is typically factory set to 50.
REMARKS GET/SET.
RETURNS The instant RSSI value and the programmed threshold.
REMOTE No.