• type is used to represent the device type. The following types are
assigned currently:
— 0 for A730MD
— 1 for A720
— 2 for A730SD
— 3 for A720B
— 4 for A733
— 5 for A723
— 6 for A440
— 7 for A733 GSM
— 8 for A731
— 9 for A732
— 10 for A740
— 11 for A740 GSM
— 12 for A724
— 15 for A723_Series 4
— 16 for A724_Series 4
— 21 for A753GSM
— 24 fir RA440
• slot and samples are the actual values programmed by means of
the SLOT command.
Note: The “slot” parameter has no relevance for the A440. The “samples”
parameter has no relevance for RA440 or the A440 (normally they
show 0).
• po is the relative output power of the device.
Note: This parameter has no relevance for the RA440 (normally shows 0).
• err_level is the error value; 0 means no error.
REMOTE Yes, GET only.
EXAMPLE # 441 info
441 info 0 31 01/01/1970 00:00:00 1.2 0 0 0 83 60 0 00:40 0
65 72 24 900 0 0 0
#
PMP
A
VAILABLE FOR RA440
DESCRIPTION Sets/returns the node’s Power Management Parameters (switches the
battery charge on/off).
PARAMETERS The lower (switch on) and the higher limit (switch off), both in volts x
10. Standard Values are 65 (for 6.5 volts) for switch on and 72 (for
7.2 volts) for switch off, for a standard 6.2 volt NiMH battery. From
these values, other thresholds are internally computed.
REMARKS GET/SET.