User's Manual
CHAPTER3
Usingterminalcommands
34
configuration and second parameter is the index size. The RA440
factory setting is:
•1st parameter: 1
• 2nd parameter: 384
REMARKS GET/SET.
RETURNS Current memory setting.
REMOTE Yes.
EXAMPLE # 441 FDEV
441 FDEV 1 16+0 64..1024 384/383 9216/9192 0
#
# 441 FDEV 1 384
441 FDEV 0
#
FREQ
0
CAUTION Do not change the frequency of your device without reason. Apart
from the fact that it might not communicate in the network anymore,
you might also violate the applicable radiocommunications laws in
your country. Depending on the destination country, some models
may also return an error message.
AVAILABLE FOR A440
DESCRIPTION Sets/returns the operating frequency.
PARAMETERS The operating frequency and step (Hz), or none in the GET version.
REMARKS GET/SET.
RETURNS The actual frequency and step, in Hz.
REMOTE Yes, SET only.
EXAMPLE # FREQ 433925000 25000
442 FREQ 0
# FREQ
442 FREQ 433925000 25000 0
#
GPRSAPNPW
A
VAILABLE FOR RA440
DESCRIPTION Sets/returns the GPRS operator network’s access point password.
PARAMETERS None or the GPRS operator network’s access point password.
REMARKS GET/SET.