User's Manual
CHAPTER3
Usingterminalcommands
31
Following is a list of available commands and an explanation of their
use.
Note: You can type uppercase or lowercase characters because the
commands are not case sensitive.
A440TMOUT
A
VAILABLE FOR RA440
DESCRIPTION Sets a timeout, after which the RA440 will turn on the A440, if no
communication to the device occurs and a command for the unit is
pending.
PARAMETERS The time in seconds.
REMARKS SET/GET.
RETURNS Error code or the seconds set.
REMOTE Yes.
EXAMPLE # A440TMOUT 60
441 A440TMOUT 0
#
# A440TMOUT
441 A440TMOUT 60 0
#
B
A
VAILABLE FOR A440
DESCRIPTION Sends a broadcast frame.
PARAMETERS None.
REMARKS After the device has sent the broadcast frame, it will listen for
answers. All valid answers will be listed with their IDs.
RETURNS A data block.
REMOTE Yes. A device getting this frame would have to wait for a random time
(2 to 10 seconds) before performing the actual broadcast; if no
terminal is active, no results will be listed. A list of stations heard, with
their RF levels, will be updated in the memory and will be available
when the BLST command is issued.
EXAMPLE # B 442
B0
# 42340 BA 0
# 34781 BA 0
#