Performing Advanced Functions
sufficient for battery power management (charge/discharge). To compute
the actual value (in °C), the following equation must be used:
Temp =
internalTemp * 400
255
- 68
days_uptime in days; together with hr:min_uptime it represents the
amount of time the device is up without a reset or watchdog
hr:min_uptime in hours:minutes format
rssi as decimal (
unsigned chars); it is the programmed value with the RSSI
command
pmp_low and pmp_high are the programmed values with the PMP
command
type is used to represent the device type; following types are assigned
currently:
0 for A730MD
1 for A720
2 for A730SD
3 for A720B
4 for A733
5 for A723
6 for A440
7 for A733GSM
8 for A731
9 for A732
10 for A740
slot and samples are currently unused
po is the power output of the device during the last frame sent; this value is
relative (a value of 20 means approx. 50 mW while a value of 175 means
approx. 500 mW)
err_level is the error value; 0 means no error
REMARKS GET only.
REMOTE Yes, GET only, and only the version without parameters. The A740 can issue the
command both remotely and locally.
EXAMPLE INFO
193 INFO 255 0 18/4/1999 21:5:11 1.0 0 0 0 91 72 40 1:46 58
65 72 0 0 15 0
#
RX
DESCRIPTION Switches the unit to permanent receive mode (for tuning purposes).
PARAMETERS None.
RETURNS Nothing.
REMARKS The system stops, and exits the command only when a key is pressed. This
command returns no message.
32