User's Manual
Performing Advanced Functions
37
REMARKS The system stops, and exits the command only when a key is pressed. This
command returns no message. Not applicable to the A733GSM.
R
EMOTE No.
E
XAMPLE TX
9193 TX 0
#
TX 1
9193 TX 0
#
TX 5
9193 TX 0
#
B
AVAILABLE FOR
A731 A733A732 A733GSM
D
ESCRIPTION Sends a broadcast frame.
P
ARAMETERS None.
R
ETURNS A data block.
R
EMARKS After the device sends the broadcast frame, it will listen for answers. All valid
answers will be listed with their IDs. Not applicable to the A733GSM.
R
EMOTE Yes. A device getting this frame would have to wait for a random time (2 to 10
seconds) before performing the actual broadcast; if no terminal is active, then no
results will be listed. A list of heard stations with their RF levels will be updated in
the memory and available whenever the BLST command is issued.
E
XAMPLE B
9193 B 0
#234 BA 0
#7851 BA 0
BLST
AVAILABLE FOR
A731 A733A732 A733GSM
D
ESCRIPTION Lists the stations heard after the last broadcast command was issued.
P
ARAMETERS None.
R
ETURNS The date and time when the broadcast was performed, the number of stations
heard, and a list with the heard stations’ ID and their respective RF levels.
R
EMARKS GET only. Not applicable to the A733GSM.
R
EMOTE Yes. The remote version will list only the first 9 stations heard.
E
XAMPLE BLST
9193 BLST 10/12/1999 12:15:04 4
2008 150
2003 177
6883 168
4027 220
#