User's Manual

Using terminal commands
36
input and then an MFR (monostable function) was issued, the port automatically
switches to output. A new MFR or similar function clears the status of the port and
starts from scratch, even if the previous command was not finished.
The A733 cannot issue the PORT command remotely, but can execute it.
E
XAMPLE For RDP:
PORT 0
9193 PORT 0 1 0
#
For RDDR:
PORT 16
9193 PORT 16 0 0
#
For ENOPC:
PORT 112
9193 PORT 112 0
#
For RPNNER:
PORT 128
9193 PORT 128 0 1 0
#
For RNS:
PORT 80
9193 PORT 80 7/5/1999 18:34:22 0
#
RX
AVAILABLE FOR
A731 A733A732 A733GSM
D
ESCRIPTION Switches the unit to permanent receive mode (for tuning purposes).
P
ARAMETERS None.
R
ETURNS Nothing.
R
EMARKS The system stops, and exits the command only when a key is pressed. This
command returns no message.
R
EMOTE No.
E
XAMPLE RX
9193 RX 0
#
TX
AVAILABLE FOR
A731 A733A732 A733GSM
D
ESCRIPTION Switches the unit to transmit mode (for tuning purposes).
P
ARAMETERS None (sends an unmodulated carrier), 1 (sends a 1 kHz modulated carrier), 0
(sends a 2 kHz modulated carrier) or 5 (sends a mixed 1 + 2 kHz modulated
carrier).
R
ETURNS Nothing.