User's Manual

Table Of Contents
CHAPTER 3
Performing Advanced Functions
32
Programming the valve voltage
The valve voltage can be programmed via the following signal
sequence:
Table 3. addSWITCH Status Information
Return value
(decimal)
Return value
(binary)
Status
32771 1000 0000 0000 0011 idle, no com-
mand pendig
32770 1000 0000 0000 0010 VALVE 1 active
32769 1000 0000 0000 0001 VALVE 2 active
32768 1000 0000 0000 0000 VALVE 1+2 active
3 0000 0000 0000 0011 Programming
mode, no com-
mand pending
32899 1000 0000 1000 0011 idle, no com-
mand pending,
solar cell con-
nected
32897 1000 0000 1000 0001 VALVE 2 active,
solar cell con-
nected
32896 1000 0000 1000 0000 VALVE 1+2 active,
solar cell con-
nected
131 0000 0000 1000 0011 Programming
mode, no com-
mand pending,
solar cell con-
nected