CHAPTER 3
Performing Advanced Functions
18
The A724 comes with a 1m cable with flying ends. A standard
cable clamp can be used to connect the solenoid. It is up to the
user to protect this cable clamp for outdoor usage.
Figure 11. The Valve Connector
Connect the positive terminal (commonly red) of the first valve to
the Sol1 pin and the negative (commonly black) terminal to the
SolCom pin (1-2). The second valve must be connected to Sol2
and the second SolCom pin.

WARNING Do not use only one SolCom wire for both valves.
The cable colors of your valve may differ from this scheme. Please
consult the manufacturer of your valves.
Note: When the polarity is reversed, the valve operation is also
reversed. The user can check the correct cabling with the
power up sequence of the A724.
When the A724 starts up (e.g. the battery is connected), it sends
immediately OFF commands to both valves (sequential).
Communicating with the RTU
You can use a Windows Hyperterminal window to connect to the
addSWITCH RTU. After you have installed the system, follow these
steps to configure the device and set the default parameters:
Note: To configure the A724 RTU, you must have a special adapter
cable (available from your Adcon distributor) and plug it into
the POWER connector.
1. Open a Hyperterminal window.
1
2
4
3
SolCom SolCom
Sol1 Sol2
white
brown
yellow
green