User's Manual
Table Of Contents
- Contents
- Chapter 1. Introduction
- Chapter 2. Using the addSWITCH
- Chapter 3. Performing Advanced Functions
APPENDIX
45
Receiver
Sensitivity (10 db S/N) -105 dBm
Image Frequency Attenuation (IF = 200kHz) 35 dB
Local Oscillator Leakage 2 nW
Adjacent Channel Attenuation 55 dB
RSSI Dynamic 90 dB
Operating Current (incl. onboard microcontroller)
c
65 mA
Transmitter (all measurements made on a 50 Ohm
resistive load)
Output Power ERP 10 dBm
Spurious Radiation (0 to 862 MHz) 2 nW
Spurious Radiation (862 MHz to 3.5 GHz) 200 nW
Adjacent Channel Power (12.5 kHz version) -32 dBm
Adjacent Channel Power (25 kHz version) -44 dBm
Occupied Bandwidth (12.5 kHz version) 8.5 kHz
Occupied Bandwidth (25 kHz version) 15 kHz
Operating Current (incl. onboard microcontroller) 50 mA
Counter Inputs V
il
00.5V
Counter Inputs V
ih
2.5 3.3 V
Pulse Counter Input Frequency 50 Hz
Pulse Counter Resolution 16 bits
Valve Output Voltage
d
,
e
515V
Valve Output Pulse 100 ms
a. Data rate is content dependent.
b. This parameter represents the tuning range; the switching range may be limited in
the software to a narrower space (even to the extent of a single channel).
c. Continuous duty.
d. The energy stored in a 4700uF capacitor is fired to the valve.
Table 5. Operational Parameters (Continued)
Parameter Min Typical Max Unit