Settingthevalvevoltage
Please note that all valves need to operate on the same voltage
because voltage cannot be set individually. The valve voltage can be
programmed via the command SBAT.
The parameter for the command SBAT is the valve operating voltage
(pulse). It is specified in tenths of volt.
If the operating voltage of your valves is 12V, issue the command:
SBAT 120
If you want to inspect the current setting, use the command SBAT
without a parameter:
SBAT
41239 SBAT 0 0 120 0
Note: The sensor supply voltage can’t be programmed—only the valve
voltage.
Returnederrorslist
Following are error messages you might get.
Commandlineinterpreter
1 — nonexistent command
2 — command line buffer overflow (input line too long)
3 — internal error
4 — reserved
5 — missing or false parameters in command
6 — operation not implemented
7 — remote operation not allowed
8 — Invalid IMEI checksum number
9 — command not supported in this configuration
Devicedescriptorsandstoragehandler
10 — device not found (attempt to perform a command on a
nonexistent device)
11 — device already exists
176 1011 xxxx VALVE 3 active
112 0111 xxxx VALVE 4active