User's Manual

CHAPTER3
Usingterminalcommands
39
41239 verb 0
#
XCONF
D
ESCRIPTION This command transmits command strings for commands (those that
are suited for this mode of operation) to the targeted RTUs. Allowed
commands are: CALC, DPE, DYNSLOT, MSTR, SBAT, SLOT, SST and
SDI.
PARAMETERS A command string.
RETURNS The replying string and error code.
REMOTE Yes.
EXAMPLE # 41240 XCONF SBAT
41240 XCONF SBAT 0 0 120 0
# 41240 XCONF CALC
41240 XCONF CALC 0 0 0
#
XDATA
D
ESCRIPTION Returns data stored for a certain device.
PARAMETERS XDATA requires a lot of parameters for specifying what to retrieve.
Please consult the A740 User Manual for detailed explanation of this
command. The output of the command is not intended to be human
readable.
RETURNS A data block.
REMOTE Yes, for a GET, but only one frame at a time.
EXAMPLE XDATA 0 8 0 255 1 0
41239 xdata 0 196 0x18
0x4A042CD0 1 0 0xF6 :0F0262645B3D
0x4A042CD0 1 1 0xF6 :0700000262640B40
0x4A042DFC 1 2 0xF6 :030000003C64
0x4A042CD0 1 3 0xF6 :030000026264
0x4A042CD0 1 4 0xF6 :030000026264
0x4A042CD0 1 5 0xF6 :F3026264
0
#
XIMME
D
ESCRIPTION Samples all inputs and immediately returns the sampled data.
PARAMETERS First parameter specifies the sample mode, which has to be 2 for raw
data. The second parameter sets the maximum packet size. If you
specify the third parameter, you can select a certain input connector.