38
TYPE
D
ESCRIPTION Requests the hardware type information of the device.
PARAMETERS None.
RETURNS The hardware type.
REMARKS GET only.
REMOTE No.
EXAMPLE TYPE
41239 TYPE A724_S4
#
VER
D
ESCRIPTION Requests the firmware version of the device.
PARAMETERS None.
RETURNS The current version.
REMARKS GET only.
REMOTE No.
EXAMPLE VER
15535 VER 1.3.0 0
#
VERB
D
ESCRIPTION Sets the verbosity level of the RTU. This command is used for
debugging only.
WARNING The RTU will consume a lot more power when the verbosity level is
greater than 0. This could discharge your battery and/or prevent from
proper operation.
PARAMETERS A verbosity level (0...255).
RETURNS Error code.
REMARKS SET only.
REMOTE No.
EXAMPLE # VERB 1
41239 VERB 0
VERB 1 # src=43 dest=9002 type=?
src=43 dest=9002 type=?
verb 0