User's Manual

CHAPTER3
Usingterminalcommands
36
SLOT
41239 SLOT 900 1 900 15 900 15 900 15 900 15 900 1 0 0 0
# slot 600 10
41239 slot 0
# slot
41239 slot 600 1 600 10 600 10 600 10 600 10 600 1 0 0 0
# slot 300 30
41239 slot 0
# slot
41239 slot 300 1 300 30 300 30 300 30 300 30 300 1 0 0 0
# slot 3600 200
41239 slot 0
# slot
41239 slot 3600 1 3600 200 3600 200 3600 200 3600 200 3600 1
0 0 0
#slot 900 3
41239 slot 0
# slot
41239 slot 900 1 900 3 900 3 900 3 900 3 900 1 0 0 0
# slot 60 2 2
41239 slot 0
# slot
41239 slot 900 1 900 3 60 2 900 3 900 3 900 1 0 0 0
#
SST
D
ESCRIPTION Sets/returns the sensor supply time of a device.
PARAMETERS The first parameter is the sensor supply time in seconds.
The second parameter specifies 0=parallel or 1=sequential
measurement. This parameter is not used for the A724 Series 4.
The third parameter addresses the channel (connector):
0— internal (can’t be modified)
1— I/O-A (INPUT)
2— I/O-B
3— I/O-C
4— I/O-D
5— Valves
6— SDI-12
Note: The A724 Series 4 supports only connector I/O-A, which is identical to
the INPUT connector. The other connector SST settings should be 0.
RETURNS Current configuration.
REMARKS GET/SET.
REMOTE Yes, SET only. For full control use XCONF.
EXAMPLE # SST 0
41239 SST 0