User's Manual

CHAPTER3
Usingterminalcommands
34
ROUTE
D
ESCRIPTION Sets/returns the routing information of a device.
PARAMETERS None, or a route (with destination) containing up to eight
intermediaries. When just the destination ID is given, the route for
this device is deleted.
RETURNS The commands success or error code and the route table.
REMARKS GET/SET.
REMOTE No.
EXAMPLE For MFS:
# ROUTE 41240 43
41239 ROUTE 0
# ROUTE
41239 ROUTE
41240 43
0
#
RSSI
D
ESCRIPTION Sets/returns the Relative Signal Strength Indicator threshold at which
the RF receiver must wake up.
PARAMETERS The threshold value. For the A724 Series 4, it can take values from 0
to 255; it is typically factory set to 100.
RETURNS The instant RSSI value and the programmed threshold.
REMARKS GET/SET.
REMOTE No.
EXAMPLE RSSI 50
41239 RSSI 0
#
RSSI
41239 RSSI 34 50 0
#
Note: The values of the RSSI threshold have no units, they are arbitrary.
RX
D
ESCRIPTION Switches the unit to permanent receive mode (for tuning purposes).
PARAMETERS None.
RETURNS Nothing.