EXAMPLE # MSTR 43
41239 MSTR 0
# MSTR
41239 MSTR 43 0
#
PMP
D
ESCRIPTION Sets/returns the node’s Power Management Parameters (switches the
battery charge on/off).
PARAMETERS The lower (switch on) and the higher limit (switch off), both in volts x
10. Standard Values are 65 (for 6.5 Volts) for switch on and 72 (for
7.2 Volts) for switch off, for a standard 6.2 Volt NiMH battery. From
these values, other thresholds are internally computed.
RETURNS The lower (switch on) and the higher limit (switch off), both in volts x
10.
REMARKS GET/SET.
REMOTE Yes, SET only.
EXAMPLE PMP 65 72
41239 PMP 0
#
PMP
41239 PMP 65 72 0
#
PORT
D
ESCRIPTION A complex command acting upon the I/O ports of a device.
PARAMETERS A control byte specifying the command the bit of the port to command
is acting on, and two 16-bit parameters, depending on the control
byte. For some commands, the control byte or the paramaters (or
both) might be missing. Refer to the A733 User Guide for a complete
command description.
RETURNS The result depends on the control byte.
REMARKS For the A724 Series4, only one analog channel is available.
REMOTE Yes.
EXAMPLE For MFS:
# PORT 212 1 20
41239 PORT 212 0
#