User's Manual
Table Of Contents
- Contents
- Chapter 1. Introduction
- Chapter 2. Using the addSWITCH
- Chapter 3. Performing Advanced Functions
CHAPTER3
Usingterminalcommands
30
organization (only index size), can be optimized for your specific
application.
The first parameter for this command is the chip configuration and
second parameter is the index size.
The following EEPROM types are currently available:
• 3– 32Kbytes (e.g. model 25256, 1 device)
• 7– 64Kbytes (e.g. model 25256, 2 devices)
RETURNS Current setting.
REMARKS GET/SET.
REMOTE Yes, SET only.
EXAMPLE FDEV
41239 fdev 7 32+32 256..4096 1280/0 51200/0 0
# FDEV 7 1280
41239 fdev 0
#
FREQ
CAUTION Do not change the frequency of your device without reason: apart
from the fact that it might not communicate in the network anymore,
you might also violate the applicable radiocommunications laws in
your country. Depending on the destination country, some models
may also return an error message.
DESCRIPTION Sets/returns the operating frequency.
PARAMETERS The operating frequency and step (Hz), or none in the GET version.
RETURNS The actual frequency and step, in Hz.
REMARKS GET/SET.
REMOTE Yes, SET only.
EXAMPLE FREQ 433925000 25000
41239 FREQ 0
#
FREQ
41239 FREQ 433925000 25000 0
#
ID
D
ESCRIPTION Sets/returns the node’s ID.
PARAMETERS The node ID.
RETURNS The node ID.