User's Manual

CHAPTER3
Usingterminalcommands
27
41239 cmds ANLG ANRT B BLST CALC DATA DATASDI DPE DYNSLOT
FDEV FREQ ID INFO MSTR PMP PORT ROUTE RSSI SBAT SLOT SST
TIME TYPE VER VERB XCONF XDATA XIMME 0
#
DATA
D
ESCRIPTION Retrieves data frames from RTUs earlier than Series 4.
PARAMETERS See the manual for the appropriate pre Series 4 RTU.
RETURNS A pre Series 4 data frame.
REMARKS Remote only. Support for pre Series 4 RTUs.
REMOTE Yes.
EXAMPLE 14446 DATA 14446 24/12/2008 16:00:00
14446 DATA 24/12/2008 16:00:00 21 37 235 255 15
0 0 0 0 89 2 0 350 0 0 0 0 0 0 2 504 1312 0 0
#
DATASDI
D
ESCRIPTION Retrieves SDI-12 data frames from RTUs earlier than Series 4.
PARAMETERS See the manual for the appropriate pre Series 4 RTUs.
RETURNS A pre Series 4 SDI-12 data frame.
REMARKS Remote only. Support for pre Series 4 RTUs.
REMOTE Yes.
EXAMPLE 14446 DATASDI 14446 24/12/2008 16:00:00
14446 DATA 24/12/2008 16:00:00 FIXME
#
DPE
D
ESCRIPTION Sets/returns the digital port event settings of a device.
PARAMETERS The first parameter is the 12-bit bitmask to specify the port bits that
will trigger a digital port event.
The second parameter is the timeout in seconds (1-65536). When the
timeout occurs without a port change on a configured port, a digital
port event will be enforced. This is useful for having regular port state
updates and additionally updates when the port state changes. Use 0
for the second parameter to turn off the timeout.
Note: A low timeout value will produce a lot of dataframes, which might
overload the radio channel transmission capacity!