User's Manual

CHAPTER3
Usingterminalcommands
25
PARAMETERS A control byte specifying the command and the analog input channel
number the command is acting on. Please look into the A733 User
Guide for a complete command description.
RETURNS The current ANLG setting.
REMARKS For the A724 Series4, only one analog channel is available.
REMOTE Yes.
EXAMPLE # ANLG 64
41239 ANLG 0
# ANLG 0
41239 ANLG 0 4 0 0 0 0 0 0 0 0 0 0 0 0
#
ANRT
D
ESCRIPTION Sets/returns the analog signal routing configuration for RTUs earlier
than Series 4.
PARAMETERS See the manual for the appropriate pre Series 4 RTU.
RETURNS The current setting.
REMARKS Remote only. Support for pre Series 4 RTUs.
REMOTE Yes.
EXAMPLE 14446 ANRT
14446 ANRT 0 1 2 3 4 5 6 7 8 9 10 11 0
#
B
D
ESCRIPTION Sends a broadcast frame.
PARAMETERS None.
RETURNS A data block.
REMARKS After the device has sent the broadcast frame, it will listen for
answers. All valid answers will be listed with their IDs.
REMOTE Yes. A device getting this frame would have to wait for a random time
(2 to 10 seconds) before performing the actual broadcast; if no
terminal is active, no results will be listed. A list of stations heard, with
their RF levels, will be updated in the memory and will be available
whenever the BLST command is issued.
EXAMPLE B
41239 B 0
#42340 BA 0
#34781 BA 0