User's Manual

Table Of Contents
CHAPTER 3
Performing Advanced Functions
40
R - Continuous measurement
C - Concurrent measurement (treated like M by RTU)
V - Verify (to get internal sensor status info)
REMOTE Yes.
EXAMPLE SDI
38193 SDI abcd abcd xmdv 0 0 0
#
COMMAND RX
DESCRIPTION Switches the unit to permanent receive mode (for tuning pur-
poses).
PARAMETERS None.
RETURNS Nothing.
REMARKS The system stops, and exits the command only when you press a
key. This command returns no message.
REMOTE No.
EXAMPLE RX
38193 RX 0
#
COMMAND TX
DESCRIPTION Switches the unit to transmit mode (for tuning purposes).
PARAMETERS None (sends an unmodulated carrier), 1 (sends a 1 kHz modulated
carrier), 0 (sends a 2 kHz modulated carrier) or 5 (sends a mixed 1
+ 2 kHz modulated carrier) or 9 (send a PN9 test sequence).
RETURNS Nothing.
REMARKS The system stops, and exits the command only when you press a
key. This command returns no message.
REMOTE No.