DPE
38193 DPE 3 60 0
#
COMMAND PORT
APPLIES TO A720B, but see comments in “Remote” on page 36.
DESCRIPTION A complex command acting upon the I/O ports of a device.
PARAMETERS A control byte specifying the command, the bit of the port the
command is acting on, and two 16-bit parameters, depending on
the control byte; for some commands, one or both of them may be
missing. However, if they are needed for a certain command but
not given, null values are implied.
The control byte’s significance is shown in Figure 7.
Figure 7. Control Byte Layout
The Port Number selects a the port that will be affected by
the command. For the A723S4, only 0000 and 0001 are
accepted.
The Command Code specifies the operation that will be
applied to the selected port.
Table 4 shows the command codes definitions.
Command Code
Port Number
Table 4. Command Code Definitions
Code Description Parameters Returns
0000 RDP – Read Data Port. This command reads the
whole 16-bit port and returns its value; the Port
Number has no significance for this command.
None A 16-bit integer and the
result (OK or ERROR).
0001 RDDR – Read Data Direction Register. This com-
mand reads the whole 16-bit Data Direction
Register and returns its value; the Port Number
has no significance for this command.
None A 16-bit integer and the
result (OK or ERROR).