User's Manual

Table Of Contents
CHAPTER 3
Performing Advanced Functions
30
RETURNS The current setting.
REMARKS Do not play with this settings, the correct setup depends on the
memory components on the pcb and is a factory setup. Contact
Adcon Telemetry for optimal index size setting.
REMOTE Yes, SET only.
EXAMPLE FDEV
38193 FDEV 1 16+0 64..1024 256/255 10240/10200 0
#
FDEV 0
38193 FDEV 0
#
Note: Depending on the device’s memory size, this command may
take several seconds to complete.
COMMAND INFO
DESCRIPTION Returns various status information.
PARAMETERS None.
5 32+16 192 768 3072
6 64 256 1024 4096
7 32+32 256 1024 4096
8 16+64 320 1280 5120
9 64+16 320 1280 5120
10 32+64 384 1536 6144
11 64+32 384 1536 6144
12 64+64 512 2048 8192
Table 3. EEPROM Types
Type Memory [kB] Min index entries Default index entries May index entries