User's Manual

Table Of Contents
CHAPTER 3
Performing Advanced Functions
24
REMOTE Yes, SET only.
EXAMPLE ID 4557
38193 ID 0
#
ID
4557 ID 4557 0
#
6556 ID 7557
6556 ID 0
#
Note: The last example shows a case where a remote node was
instructed to change its own ID from 6556 to 7557. Even if it
changed its ID, it answers with the old ID in order to cor-
rectly finish the transaction.
COMMAND SLOT
 CAUTION Changing these parameters may adversely affect the
ability of the device to operate for extended periods under low
solar radiation conditions.
DESCRIPTION Sets/returns the sampling interval and rate.
PARAMETERS The
interval
(1-43200),
rate
(0-255) and optional the
connector
(0-
6). If the connector is not specified, the setting applies to all con-
nectors except SDI.
interval
represents the time (in seconds) elapsed between two slots
stored in the internal memory, while
rate
represents the numbers of
samples used to build the average that will be stored. The possible
connectors are listed in Table 2.
Table 2. Connectors
0 INTERNAL
1-4 IOA-IOD, only IOA and IOB
available on A723 Series 4
5 VALVES, not available on A723 Series 4
6 SDI