User's Manual

Table Of Contents
CHAPTER 3
Using terminal commands
23
REMARKS GET/SET.
REMOTE Yes, SET only.
EXAMPLE FREQ 433925000 25000
38193 FREQ 0
#
FREQ
38193 FREQ 433925000 25000 0
#
COMMAND RSSI
DESCRIPTION Sets/returns the Relative Signal Strength Indicator threshold at
which an RF receiver must wake up.
PARAMETERS The threshold value. For the A723 Series 4, it can take values from
0 to 255; it is typically factory set to 101.
RETURNS The instant RSSI value and the programmed threshold.
REMARKS The factory default is set to 101units. The RSSI threshold is used to
detect if any radio activity is on the channel. The value set must be
approximately 30% higher than the actual measured value when
no signal is present on the channel. To measure the actual value,
use the command RSSI with no variables or parameters.
REMOTE No.
EXAMPLE RSSI 58
38193 RSSI 0
#
RSSI
38193 RSSI 44 58 0
#
COMMAND ID
DESCRIPTION Sets/returns the node’s ID.
PARAMETERS The node ID.
RETURNS The node ID.
REMARKS GET/SET.