Datasheet

Guide to Starters Page 16 of 17
9.6 DEOS
®
ST 173 SAFETY starter
DEOS St 173 SAFETY starter for fluorescent lamps in single circuits
DEOS St 173 SAFETY starter for fluorescent lamps L15W ...32W and
OSRAM DULUX
L 18W and 24W in single circuits for inductive
(> 60,000 switching cycles) and capacitive operation
(> 30,000 switching cycles).
Reliably disconnects faulty lamps under inductive or capacitive
operating conditions. There is therefore no need to replace a single
faulty lamp instantly. This in turn means longer re-lamping intervals
and greater efficiency.
Prevents unnecessary power consumption due to short-circuit currents
as DEOS St 172 SAFETY switch-off at the end of lamp life.
Protects the control gear and luminaire holders.
With red SAFETY button which can be reset for immediate operation again.
Service life: DEOS St 173 SAFETY starter approx. 10 years inductive and approx. 5 years
capacitative (for 2 switching operations per day).
Extension of lamp life by 20%.
Reason: Both lamp electrodes are evenly heated each time the lamp is ignited thanks to the
symmetrical design of the bimetallic strip.
Self-extinguishing plastic casing made of Makrolon. Class V0
Equipped with special radio-interference suppression capacitor (foil winding capacitor).
Suitable for 220V-240V AC operation, 50/60 Hz
Cannot be used for OSRAM DULUX
S/E, D/E, T/E or T/E IN.
When the luminaire is used for the first time, push in the red SAFETY button until it clicks.
Application: For indoor and outdoor lighting, particularly where it is essential for burnt-out
lamps to be reliably shut down.
-20°C to +80°C
ENEC 10 VDE
CE label since 01.01.97
Protection class II
According to international standard IEC 155, as per Fig. B.1
Length IEC max. 40.3 mm
Diameter IEC max. 21.5 mm
From stock
Referen
ce
Standard pack
EAN
St 173 8x25er Tray OSRAM
25/200 4050300854120
Temperature range
Approval marks
Label
Protection class
Dimensions
Product features
Availability
Technical
information
Range