Guide to starters 1 Contents 1 Contents ..................................................................................................................................................... 2 2 Introduction ................................................................................................................................................. 4 3 Definitions (important technical parameters of a starter)............................................................................ 4 4 5 3.
10 Technical data sheets ........................................................................................................................... 11 10.1 ST 111 HT LONGLIFE starter .............................................................................................. 11 10.2 ST 111 LONGLIFE starter ..................................................................................................... 12 Starter St 111 LONGLIFE, for fluorescent lamps in single circuits ........................
2 Introduction The function of starters is to preheat the electrodes of fluorescent lamps and generate an ignition pulse. While the lamps are in operation the starters should consume little or no power and be ready to operate again as soon as the fluorescent lamps have been switched off. A high-quality starter will last at least 40,000 on/off switching operations (such as OSRAM ST 111 LONGLIFE). ® The DEOS SAFETY Starter also reliably switches off the fluorescent lamps at the end of their lives.
4 Starters ST 111 / ST 151 (LONGLIFE starters) 4.1 Design The glow starter contains the actual starter element, the glow igniter, and the radio interference suppression capacitor. It is connected parallel to the lamp in series with the lamp electrodes.
The bimetallic contacts cool down and open again. The energy stored in the choke now discharges. (induction law) A voltage pulse (Umax) is generated which ignites the lamp. Once the lamp has ignited only the lamp voltage (UL) is applied at the glow starter. This voltage is less than the partial discharge inception voltage. It is so low that there can be no further glow discharge between the bimetallic contacts.
5 DEOS® starters ST 171 / ST 172 / ST 172 SAFETY 5.1 Design In contrast to the starters in Section 4, the DEOS coefficient) and a bimetallic switch. ® starter has an NTC resistor (negative temperature ® Figure 3: Circuit diagram for the DEOS SAFETY starter 5.2 Operation Ignition as described for the starters in Section 4.2. In addition, fluorescent lamps that are faulty or at the end of their lives are safely and reliably shut down. 5.
6 Overview of starters An overview of the types currently available is given below.
7 RoHS The starters meet RoHS requirements (Reduction of Hazardous Substances). The glass used (bulb, exhaust stem, flare) is lead-free. 8 Disposal The starters may be thrown away with household waste. 9 Troubleshooting 9.1 Observation: the lamp fails to ignite, the starter switches without interruption Cause: The lamp voltage is too high (lamp at the end of its life) Remedy: Replace the (compact) fluorescent lamp and starter (ST 111 LONGLIFE/ ST 151 LONGLIFE) 9.
9.6 Observation: the lamp does not start, the starter casing has a brown discoloring Cause: The starter is at the end of its life, the bimetallic strips can no longer close Remedy: Replace the lamp and starter 9.6 Observation: radio interference Cause: The compensating capacitor is missing from the starter or is faulty Remedy: Replace the starter 9.7 Observation: the lamp ignites and goes out at short intervals Cause: The lamp is at the end of its life Remedy: Replace the lamp and starter 9.
Technical data sheets 9.1 ST 111 HT LONGLIFE starter Technical information High-temperature St 111 HT LONGLIFE starter, for fluorescent lamps in single circuits Product features St 111 HT LONGLIFE starter for fluorescent lamps L4W ...65W, 80W and OSRAM DULUX L 18W, 24W, 36W in single circuits. Life time > 60,000 switching cycles inductive operation. Life time > 20,000 switching cycles capacitive operation Life time in acc. to IEC 155: minimum of 6000 switching cycles.
9.2 ST 111 LONGLIFE starter Technical information Starter St 111 LONGLIFE, for fluorescent lamps in single circuits Product features St 111 LONGLIFE starter for fluorescent lamps L4W...65W, 80W and OSRAM DULUX L 18W, 24W, 36W in single circuits. Life time > 60,000 switching cycles inductive operation Life time > 20,000 switching cycles capacitive operation Life time in acc. to IEC 155 , minimum 6000 switching cycles. Switching time: 1 minute, 30s on, 30s off Service life approx.
9.3 ST 151 LONGLIFE starter Technical information Starter St 151 LONGLIFE, for fluorescent lamps in series circuits Product features St 151 LONGLIFE starter for fluorescent lamps L4W...22W and OSRAM DULUX L 18W in series circuit. Life time > 18,000 switching cycles inductive operation, Life time > 9000 switching cycles capacitive operation. Life time in acc. to IEC 155: minimum of 6000 switching cycles, Switching time: 1 minute, 30s on, 30s off Service life approx.
DEOS® ST 171 SAFETY starter 9.4 Technical information DEOS St 171 SAFETY starter for fluorescent lamps in single circuits Product features DEOS St 171 SAFETY starter for fluorescent lamps L36W ...65W and OSRAM DULUX L 36W in single circuits for inductive (> 60,000 switching cycles) and capacitive operation (> 30,000 switching cycles). Reliably disconnects faulty lamps under inductive or capacitive operating conditions.
9.5 DEOS® ST 172 SAFETY starter Technical information DEOS St 172 SAFETY starter for fluorescent lamps in series circuits Product features DEOS St 172 SAFETY starter for fluorescent lamps L15W ...22W and OSRAM DULUX L 18W in series circuits for inductive (> 20,000 switching cycles) and capacitive operation (> 10,000 switching cycles). Reliably disconnects faulty lamps under inductive or capacitive operating conditions.
9.6 DEOS® ST 173 SAFETY starter Technical information DEOS St 173 SAFETY starter for fluorescent lamps in single circuits Product features DEOS St 173 SAFETY starter for fluorescent lamps L15W ...32W and OSRAM DULUX L 18W and 24W in single circuits for inductive (> 60,000 switching cycles) and capacitive operation (> 30,000 switching cycles). Reliably disconnects faulty lamps under inductive or capacitive operating conditions.
10 Literature Betriebsgeräte und Schaltungen für elektrische Lampen, C.H. Sturm / E. Klein, ISBN 3-8009-1586-3 Lamps and lighting J.R. Coaton / A.M. Marsden, ISBN 0-340-64618-7 Grundlagen Beleuchtungstechnik R. Bear, ISBN 3-341-01497-7 Elektrotechnik, Lexikon für die Praxis R. Müller, ISBN 3-341-01297-4 Subject to change without notice. Errors and omission excepted. This information supersedes all previous information.