L Manual
65
5.1 Unique features of the new OSRAM CFL ECG
• Up to 12 lamp types can be operated on 1-lamp ECG
DULUX D/E 18 W, DULUX T/E 18 W 2
DULUX D/E 26 W, DULUX T/E 26 W )
+ DULUX T/E 26 W IN (amalgam) 3
DULUX T/E 32 W, DULUX T/E 32 W IN (amalgam) 2
DULUX T/E 42 W DULUX T/E 32 W IN (amalgam) 2
DULUX T/E 57 W IN (amalgam) 1
FC 22 W 1
FC 40 W 1
Σ = 12 lamps
• For the first time, DULUX IN (amalgam) can also be operated on
the DIM ECG
• Halving of the range of ECG products from 4 to 2 types of ECG
• Lamp starting with optimized filament preheating inside 0.6 s
• 2-lamp ECGs now as small as 1-lamp ECGs (K3 housing)
• Dimming range 3…100 % luminous flux
• DALI and TouchDim interface can be operated in an ECG, e.g. on
DALI dimmer or TouchDim sensor
• Highest energy efficiency thanks to cutoff technology
• Automatic safety shutdown on lamp defect and at the end of the
lamp life (EoL T2)
• Optional cable clamps for snapping into the housing
Figure 49: Principle Optional cable clamps for snapping into the
housing