Brochure
QUICKTRONIC
INTELLIGENT QTi GII
GL LB EU&LM FT, Edition: 13.03.2012. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guaranty will be provided.
TECHNICAL INFORMATION
03
Inrush current and max. number of ECG per circuit breaker
ECG
Inrush Current Max. number of ECG per circuit breaker
Ip [A] TH [µs] B: 10A B: 16A C: 16 A
QTi 1x14/24/21/39 GII 24 230 17 28 47
QTi 2x14/24/21/39 GII 53 190 8 13 22
QTi 1x28/54/35/49 GII
24 230 17 28 47
QTi 2x28/54/35/49 GII 53 190 8 13 22
QTi 1x35/49/80 GII 53 190 8 13 22
QTi 2x35/49/80 GII 39 230 5 9 15
QTi 2x35/49/80 60 230 5 9 15
Standards and approval marks
Dimensions & weight
Description
Safety: acc. to EN 61347-2-3 / IEC 61347-2-3
Radio interference acc. EN 55015: 2006 + A1: 2007 + A2: 2009
Harmonic content: acc. to EN 61000-3-2 / IEC 61000-3-2
Immunity: acc. to EN 61547 / IEC 61547
A
pproval marks:
Description Length
[mm]
Width
[mm]
Height
[mm]
Distance
mounting
holes [mm]
Weight [g]
QTi 1x14/24/21/39 GII 360 30 21 350 220
QTi 2x14/24/21/39 GII 360 30 21 350 250
QTi 1x28/54/35/49 GII
360
30 21
350 240
QTi 2x28/54/35/49 GII 360 30 21 350 270
QTi 1x35/49/80 GII 360 30 21 350 240
QTi 2x35/49/80 GII 425 30 21 415 400
QTi 2x35/49/80 425 30 21 415 400