Datasheet

Product Product
reference number
OSRAM LUMILUX
®
XT – T8 tubular, G13 base
L 18W/830 XT 4008321209085 18 1350 LUMILUX Warm White 80...89 26 590 25
L 18W/840 XT 4008321209108 18 1350 LUMILUX Cool White 80...89 26 590 25
L 18W/865 XT 4008321209122 18 1250 LUMILUX Cool Daylight 80...89 26 590 25
L 36W/830 XT 4008321209146 36 3300 LUMILUX Warm White 80...89 26 1200 25
L 36W/840 XT 4008321209160 36 3300 LUMILUX Cool White 80...89 26 1200 25
L 36W/865 XT 4008321209221 36 3250 LUMILUX Cool Daylight 80...89 26 1200 25
L 58W/830 XT 4008321209344 58 5200 LUMILUX Warm White 80...89 26 1500 25
L 58W/840 XT 4008321209320 58 5200 LUMILUX Cool White 80...89 26 1500 25
L 58W/865 XT 4008321923622 58 5000 LUMILUX Cool Daylight 80...89 26 1500 25
Product Switching Average life Service life Average life Service life
reference cycle (LLG, inductive) (LLG, inductive) (ECG, hot restart) (ECG, hot restart)
all XT 165'/15' (as per IEC) 28000 21000 50000 42000
all XT 11 h/1 h 44000 35000 50000 42000
TECHNICAL DATA
Product Product
reference number
OSRAM LUMILUX
®
XXT – T8 tubular, G13 base
L 18W/830 XXT 4008321923646 18 1350 LUMILUX Warm White 80...89 26 590 25
L 18W/840 XXT 4008321923660 18 1350 LUMILUX Cool White 80...89 26 590 25
L 18W/865 XXT 4008321923684 18 1250 LUMILUX Cool Daylight 80...89 26 590 25
L 36W/830 XXT 4008321923707 36 3250 LUMILUX Warm White 80...89 26 1200 25
L 36W/840 XXT 4008321923721 36 3250 LUMILUX Cool White 80...89 26 1200 25
L 36W/865 XXT 4008321923745 36 3150 LUMILUX Cool Daylight 80...89 26 1200 25
L 58W/830 XXT 4008321923769 58 5150 LUMILUX Warm White 80...89 26 1500 25
L 58W/840 XXT 4008321923783 58 5150 LUMILUX Cool White 80...89 26 1500 25
L 58W/865 XXT 4008321923806 58 5000 LUMILUX Cool Daylight 80...89 26 1500 25
Product Switching Average life Service life Average life Service life
reference cycle (LLG, inductive) (LLG, inductive) (ECG, hot restart) (ECG, hot restart)
all XXT 165'/15' (as per IEC) 44000 40000 80000 66000
all XXT 11 h/1 h 63000 58000 90000 75000
10 0000 20 000 30 000
60
50
70
80
90
100
%
40 000
50 000 h
LLG-11/1 cycle
ECG hot restart-IEC and 11/1 cycle
LLG-IEC cycle
Luminous flux behavior
Hours burned
Luminous fl ux behavior and survival rate of the XT
20 0000 40 000 60 000
60
50
70
80
90
100
%
80 000
100 000 h
Hours burned
LLG-11/1 cycle
ECG hot restart-11/1 cycle
ECG hot restart-IEC cycle
LLG-IEC cycle
Luminous flux behavior
Luminous fl ux behavior and survival rate of the XXT