Datasheet

HALOTRONIC
®
for remote installation
HTL 105/230-240
HTL 225/230-240
Technical
Information
Edition: Aug. 2010
Subject to change
Technical data:
Reference:
HTL 105/230-240 HTL 225/230-240
for lamp:
1x100/1x90/1x75/1-2x50/
1-3x35/2-5x20/4-10x10/7-21x5
1-2x100/1-2x90/1-3x75
1-4x50/2-6x35/3-11x20/
5-22x10/10-45x5
Line voltage: 230 - 240 V
Line current:
0.44 A
eff.
0.90 A
eff.
Line frequency: 0; 50 - 60 Hz
Voltage at the lamp (@ 230V):
11.3 V (35 W),
11.6 V (105 W)
11.7 V (50 W),
11.6 V (225 W)
Max. lamp wattage: 105 W 225 W
Losses: max. 6 W (105 W) max. 9 W (225 W)
Partial load: 35 W - 105 W 50 W - 225 W
Max. safe operating voltage: 207 - 264 V
AC
; 176 - 275 V
DC
Operating frequency: App. 40 kHz App. 50 kHz
Power factor: > 0.95 > 0.95
Safety:
Radio interference:
Harmonic content:
Immunity:
Performance:
EN 61347
EN 55015 (A1: 2007)
EN 61000-3-2
EN 61547
EN 61047
Temperature range: -20 °C to +50 °C
t
c
: 80 °C 85 °C
Galvanic insulation between
primary and secondary side:
4 kV
eff.
Max. inrush current:
App. 0.6 A
eff.
(105 W) App. 1.5 A
eff.
(225 W)
Dimming:
trailing or
leading edge phase control
No-load proof: yes
Protection against short-
circuits, overload and
overtemperature:
automat. switch off, reversible
Connections: screw terminals
12 V-wiring: max. 2 m
Cable types for primary side:
H03VV-F2x0.50 mm²; H03VV-F2x0.75 mm²;
H05VVH2-F2x0.75 mm²; H03VVH2-F2x0.75 mm²;
NYM-O 2x1.5 mm²; NYM-J 3x1.5 mm²; H05VV-F2x2.5 mm²
Cable types for secondary side:
H03VV-F2x0.75 mm²; H05VVH2-F2x0.75 mm²; NYM-O 2x1.5 mm²;
H05VV-F2x1.5 mm²; H05VV-F2x2.5 mm²; NYM-J 3x1.5 mm²;
NYM-J 3x2.5 mm²
Terminal on primary: max. 2.5 mm²
Terminal on secondary: max. 4.0 mm²
Geometry (l x w x h): 170 mm x 44 mm x 34 mm
Weight: app. 160 g app. 225 g
Marks:

Summary of content (2 pages)