Datasheet

Note
:
*Measurement in accordance with EN 60081, annex C.
The lamps meet EN 60081 and EN 61195 requirements.
ECG’s have to meet EN 61347-2-3 and EN 60921 requirements.
Technical Information FL
T5 FH 14W HE
LUMILUX
fluorescent lamp with 16 mm diameter
available light colours: Cool Daylight (865), Cool White (840), White (835), Warm White (830), INTERNA (827)
20 percent more efficient than T8-lamps (High Efficiency)
max. luminous efficiency at 35° up to 96 lm/W (LC 8 40/830/827) resp. 89 lm/W (LC 865)
very good colour rendering (R
a
80 ... 89)
Frequency (Hz) : > 20 KHz (ECG)
Lamp wattage (W) : 14
Nominal current (ECG-operation) (A) : 0,165
Lamp arc voltage UL after switch-on (V) : 86
System power (with IEC reference ballast)
(W) : 16,0
Pre-heat current IEC 81 (mA) : 210
Luminance LF 840 (cd/cm²)
: 1,7
Average life time (
50% failure rate
) (h) : 24000 (ECG)
Economical life time
(80% lum. flux from initial 100h value)
(h) : 18000 (ECG)
FH 14W/865 HE 1100 80...89 6500
FH 14W/840 HE 1200 80…89 4000
** at >20 KHz operation and aged
100h ; 25° ambient temperature
PHYSICAL DIMENSIONS
PRODUCT FEATURES
Technical Data
Life Time*
PHOTOMETRICAL DATA
554,9
±
1,2
549,0
563,2
16,0
FH 14W/835 HE
1200 80...89 3500
FH 14W/830 HE
1200 80…89 3000
FH 14W/827 HE
1200 80...89 2700
Cap: G5/11x15
Labeling i
n brand OSRAM
Rated luminous flux** (lm)
Colour rendering index (R
a
) Colour temperature (K)
FL M
-
M, edition: 04/06
Reserved for changes – Data serve for orientation.
[in mm]