Datasheet

DULUX
®
T/E PLUS & QUICKTRONIC
®
Edition 01.2014. Subject to change without notice. Errors and omissions excepted.Always make sure to use the most recent
release.
LP LPD MK
TECHNICAL INFORMATION 03
Electrical Data
2
Lamps operated with HF
3
reference control gear at 25 °C (100 h aged) ambient temperature
DULUX
®
T/E PLUS
Lamp Voltage rated
[V]
Lamp Current rated
[mA]
Lamp Power rated
[W]
13 W
77
165
12.5
18 W
80
210
16.5
26 W
80
300
24.0
32 W
100
320
32.0
42 W
135
320
43.0
Photometrical Data at 25 °C (100 h aged) ambient temperature
4
DULUX
®
T/E PLUS
Light Color
LUMILUX
®
Color Rendering
Index (CRI),
Ra
Lumi-nance
(LC
5
840)
[cd/cm²]
Target
Color
Coordinate
X
Target
Color
Coordinate
Y
Nominal
Luminous
Flux
[lm]
Efficacy
25 °C
[lm/W]
13 W
827 INTERNA
80 … 89
4.2
0.463
0.420
900
72
13 W
830 Warm White
80 … 89
4.2
0.440
0.403
900
72
13 W
840 Cool White
80 … 89
4.2
0.380
0.380
900
72
18 W
827 INTERNA
80 … 89
4.7
0.463
0.420
1200
73
18 W
830 Warm White
80 … 89
4.7
0.440
0.403
1200
73
18 W
840 Cool White
80 … 89
4.7
0.380
0.380
1200
73
26 W
827 INTERNA
80 … 89
6.0
0.463
0.420
1800
75
26 W
830 Warm White
80 … 89
6.0
0.440
0.403
1800
75
26 W
840 Cool White
80 … 89
6.0
0.380
0.380
1800
75
32 W
827 INTERNA
80 … 89
6.5
0.463
0.420
2400
75
32 W
830 Warm White
80 … 89
6.5
0.440
0.403
2400
75
32 W
840 Cool White
80 … 89
6.5
0.380
0.380
2400
75
42 W
827 INTERNA
80 … 89
7.0
0.463
0.420
3200
74
42 W
830 Warm White
80 … 89
7.0
0.440
0.403
3200
74
42 W
840 Cool White
80 … 89
7.0
0.380
0.380
3200
74
2
According to IEC 60929
3
High Frequency
4
Measurement in accordance with IEC 60901, annex C and the relevant annex on rated colour characteristics in IEC 60081.
5
Light Color