Datasheet
DULUX
®
L LUMILUX
®
& QUICKTRONIC
®
Edition 08.2013. Subject to change without notice. Errors and omissions excepted.Always make sure to use the most
recent release.
LP LPD MK
TECHNICAL INFORMATION
5
Lifetime
8
DULUX
®
L
LUMILUX
®
ECG
9
preheated
IEC switching cycle
10
CCG
IEC switching cycle
B50
11
20000 h
10000
Service life time
12
13000 h
7500
LLMF
13
2000 h
0.90
0.85
LLMF 4000 h
0.84
0.78
LLMF 6000 h
0.82
0.76
LLMF 8000 h
0.81
0.75
LLMF 12000 h
0.78
-
LLMF 16000 h
0.78
-
LLMF 20000 h
0.76
-
LSF
14
2000 h
0.99
0.99
LSF 4000 h
0.99
0.99
LSF 6000 h
0.99
0.97
LSF 8000 h
0.99
0.85
LSF 12000 h
0.95
-
LSF 16000 h
0.80
-
LSF 20000 h
0.50
-
8
Measurement in accordance with IEC 60901, annex C.
9
Electronic Control Gear
10
Switching cycle 165 min. on, 15 min. off (according to IEC)
11
Average rated lamp life (B50) is the average value of the life values of individual lamps operated under standardized conditions (50%
failure). In other words, this is the operation time at which, for a standardized 3-hour switching cycle (165 minutes on / 15 minutes off,
see annex C, IEC 60901), 50% of a sample population of lamps have failed.
12
Service life time is the mathematical life time (maintenance multiplied with the % of failed lamps e.g. B10) for lamps in an installation
after which the installation luminous flux (100 h value) decreased with 30 % (decrease in luminous flux and failed lamps) for indoor
lighting.
13
Lamp Lumen Maintenance Factor (Lamp luminous flux in %): Ratio of the luminous flux of a specific quantity of lamps at a defined
number of hours of operation to their luminous flux at 100 h
14
Lamp Survival Factor (Lamp Survival in %): Ratio of the number of electrically intact lamps to the total number of lamps