Datasheet
DULUX
®
F & QUICKTRONIC
®
GL LB EU&LM FT, Edition: 26.02.2014. Subject to change without notice. Despite careful review, the possibility of mistakes cannot be excluded – no guarantee will be
provided.
TECHNICAL INFORMATION
4
Lifetime
8
DULUX
®
F
ECG
9
preheated
IEC switching cycle
10
CCG
IEC switching cycle
B50
11
13000
10000
Service Lifetime
12
9100
6500
LLMF
13
2000 h
0.90
0,85
LLMF 4000 h
0.86
0.80
LLMF 6000 h
0.83
0.77
LLMF 8000 h
0.81
0.75
LLMF 10000 h
0.80
-
LSF
14
2000 h
0,99
0.99
LSF 4000 h
0.99
0.99
LSF 6000 h
0.95
0.95
LSF 8.000 h
0.88
0.81
LSF 10.000 h
0.75
-
Logistic Data
Description
EAN 10
EAN 40
Packaging
Unit
DULUX
®
F 18W/827
4050300333564
4050300333571
10
DULUX
®
F 18W/830
4050300333540
4050300333557
10
DULUX
®
F 18W/840
4050300333526
4050300333533
10
DULUX
®
F 24W/827
4050300333625
4050300333632
10
DULUX
®
F 24W/830
4050300333601
4050300333618
10
DULUX
®
F 24W/840
4050300333588
4050300333595
10
DULUX
®
F 36W/827
4050300312187
4050300312194
10
DULUX
®
F 36W/830
4050300299051
4050300299068
10
DULUX
®
F 36W/840
4050300299037
4050300299044
10
8
Measurement in accordance with IEC 60901, annex C.
9
Electronic Control Gear
10
Switching cycle 165 min. on, 15 min. off (according to IEC)
11
Average rated lamp life (B50) is the average value of the life time for an entity of lamps operated under standardized
conditions until 50% failure. In other words, this is the operation time at which, for a standardized 3-hour switching cycle
(165 minutes on / 15 minutes off (according to IEC)), 50% of a sample population of lamps have failed.
12
Service life time is the mathematical life time (maintenance multiplied with the % of failed lamps e.g. B10) for lamps in
an installation after which the installation luminous flux (100 h value) decreased by 30% (decrease in luminous flux and
failed lamps) for indoor lighting
13
Lamp Lumen Maintenance Factor (Lamp luminous flux in %): Ratio of the luminous flux of a specific quantity of lamps
at a defined number of hours of operation to their luminous flux at 100 h
14
Lamp Survival Factor (Lamp survival in %): Ratio of the number of electrically intact lamps to the total number of lamps