Datasheet

DULUX
®
D/E & QUICKTRONIC
®
Edition 08.2013. Subject to change without notice. Errors and omissions excepted. Always make sure to use the most recent release.
LP LPD MK
TECHNICAL INFORMATION 09
Lamp
ECG
EAN 10 ECG
Luminous
flux @25°C
[lm]
System
power
[W]
I
N
[A]
Power
Factor
ECG
[λ]
System
luminous
efficacy
[lm/W]
Length
[mm]
Width
[mm]
Height
[mm]
Distance
between
holes
[mm]
Ta
[°C]
DULUX
®
D/E 26W
QTi DALI-T/E 1x18-57 DIM
4008321060808
1800
29.0
0.130
0.97
62
123
79
33
129.5
+10…+50
QTi DALI-T/E 2x18-42 DIM
4008321060822
3600
56.0
0.250
0.98
64
123
79
33
129.5
+10…+50
QTi-T/E 1x18-57 DIM
4008321060860
1800
29.0
0.130
0.97
62
123
79
33
129.5
+10…+50
QTi-T/E 2x18-42 DIM
4008321060846
3600
56.0
0.250
0.98
64
123
79
33
129.5
+10…+50
QTP-M 1x26-42
4008321329134
1750
27.0
0.120
0.95
65
103
67
31
110.0
-20 … +50
QTP-M 2x26-32
4008321329158
3500
53.0
0.240
0.97
66
123
79
33
129.5
-20 … +50
QTP-M 2x26-42
4008321110022
3600
54.0
0.230
0.97
67
123
79
33
129.5
-20 … +50
QTP-T/E 1x26-42, 2x26 (1x)
4008321537089
1750
28.0
0.130
0.95
63
103
67
31
110.0
-20 … +50
QTP-T/E 1x26-42. 2x26 (2x)
3500
54.0
0.240
0.98
65
QT-ECO 1x26/220-240 S
4008321065971
1600
23.5
0.180
0.6c
68
80
40
22
72-75
-15 … +50
QT-ECO T/E 2x26/220-240
4050300804002
3500
53.0
0.250
0.95
66
150
41
28
140.0
-15 … +50
For more information on ECG refer to http://www.osram.com/ecg
For more information on System Guarantee refer to http://www.osram.com/guarantee
In case of lamp breakage: www.osram.com/brokenlamp
For more information technical Information see Technical guide. Free download at www.osram.com