Datasheet
9
TS 46365 OSRAM / POWERSTAR HQI 106_T001_GB 2/22.04.2009
®
UV
FILTER
1 2
POWERSTAR
®
HQI
®
-TS
HQI-TS HQI-TS HQI-TS HQI-TS HQI-TS HQI-TS
250 W 250 W 250 W 400 W 400 W 400 W
WDL NDL D NDL D, NAV ballast D, HQI ballast
Lamp reference HQI-TS 250W/WDL HQI-TS 250W/NDL HQI-TS 250W/D HQI-TS 400W/NDL HQI-TS 400W/D HQI-TS 400W/D
Nominal luminous flux lm 22000 20000 20000 38000 37000 31000
Luminous efficacy lm/W 88 82 82 90 90 89
Light colour/Colour appearance WDL NDL D NDL D D
Colour temperature K 3200 4200 5100 4200 5200 5600
Colour rendering index R
a
80 88 93 88 93 90
Lamp wattage W 250 250 250 400 400 350
Lamp voltage V 110 100 100 120 125 120
Lamp current A 2.8 3 3 4.1
1)
4.1 3.6
Ignition voltage min./max. kVs 3.6/5 3.6/5 3/5 3/5 3/5 3/5
Base Fc2 Fc2 Fc2 Fc2 Fc2 Fc2
Diameter d mm 25 25 25 31 31 31
Length max. I mm 163 163 163 206 206 206
LCL a mm 81.5 81.5 81.5 103 103 103
Burning position p 45 p 45 p 45 p 45 p 45 p 45
Average lamp life h 12000 12000 12000 12000 12000 12000
Max. perm. outer bulb temp. °C 650 650 650 650 650 650
Max. perm. pinch temp. °C 300 300 300 300 300 300
PF corr. cap. at 50 Hz µF 32 32 32 45 45 35
EAN 4050300436012 4050300436036 4050300436050 4050300304090 4050300015385 4050300015385
Standard pack Qty 12 12 12 12 12 12
Figure No. 1 1 1 2 2 2
Circuit (see page 22) Fig. no. 2/3 2/3 2 2/3 2 2
ILCOS MD/UB-250/32/1B- MD/UB-250/42/1B- MD/UB-250/51/1A- MD/UB-400/42/1B- MD/UB-400/52=56/ MD/UB-400/52=56/
H-Fc2-25/163/P45 H-Fc2-25/163/P45 H-Fc2-25/163/P45 H-Fc2-31/206/P45 1A-H-Fc2-31/206/P45 1A-H-Fc2-31/206/P45
1) Operate only with NAV control gear.
Survival rate HQI-TS 250/NDL, /D
2000 4000 6000 80000 10000
12000
100
80
60
40
20
0
Survival rate in %
Hours burned
Luminous flux behaviour HQI-TS 250/NDL, /D
2000 4000 6000 80000 10000
12000
100
80
60
40
20
0
Luminous flux in %
Hours burned
Survival rate HQI-TS 250/WDL, 400/NDL
2000 4000 6000 80000 10000
12000
100
80
60
40
20
0
Survival rate in %
Hours burned
Luminous flux behaviour HQI-TS 250/WDL, 400/NDL
2000 4000 6000 80000 10000
12000
100
80
60
40
20
0
Luminous flux in %
Hours burned
Survival rate HQI-TS 400/D
2000 4000 6000 80000 10000
12000
100
80
60
40
20
0
Survival rate in %
Hours burned
Luminous flux behaviour HQI-TS 400/D
2000 4000 6000 80000 10000
12000
100
80
60
40
20
0
Luminous flux in %
Hours burned