Datasheet
3
TS 46365 OSRAM / POWERSTAR HQI 106_T001_GB 2/22.04.2009
®
UV
FILTER
1
POWERSTAR
®
HQI
®
-T
HQI-T HQI-T HQI-T HQI-T
70 W 70 W 150 W 150 W
WDL NDL WDL NDL
Lamp reference HQI-T 70W/WDL HQI-T 70W/NDL HQI-T 150W/WDL HQI-T 150W/NDL
Nominal luminous flux lm 5300 5800 13000 13000
Luminous efficacy lm/W 71 77 87 87
Light colour/Colour appearance WDL NDL WDL NDL
Colour temperature K 3000 4200 3000 4200
Colour rendering index R
a
76 84 77 85
Lamp wattage W 75 75 150 150
Lamp voltage V 95 100 100 100
Lamp current A 1 1 1.8 1.8
Ignition voltage min./max. kVs 3.6/5 3.6/5 3.6/5 3.6/5
Base G12 G12 G12 G12
Diameter d mm 25 25 25 25
Length max. I mm 84 84 84 84
LCL a mm 56 56 56 56
Burning position universal
1)
universal
1)
universal
1)
universal
1)
Average lamp life h 9000 9000 9000 9000
Max. perm. outer bulb temp. °C 500 500 550 550
Max. perm. pinch temp. °C 280 280 280 280
PF corr. cap. at 50 Hz µF 12 12 20 20
EAN 4050300412993 4050300488424 4050300873664 4050300488448
Standard pack Qty 12 12 12 12
Figure No. 1 1 1 1
Circuit (see page 22) Fig. no. 2/5 2/5 2/5 2/5
ILCOS MT/UB-70/30/ MT/UB-70/42/ MT/UB-150/30/ MT/UB-150/42/
2A-H-G12-25/84 1B-H-G12-25/84 2A-H-G12-25/84 1B-H-G12-25/84
1) For horizontal burning position, mount the holder in the manner that the lamp electrodes are arranged one on top of the other.
Survival rate HQI-T 70/WDL
10000
100
80
60
40
20
0
Survival rate in %
Hours burned
2000 3000 4000 5000 6000 8000 90007000
Luminous flux behaviour HQI-T 70/WDL
10000
100
80
60
40
20
0
Luminous flux in %
Hours burned
2000 3000 4000 5000 6000 7000 8000 9000
Survival rate HQI-T 70/NDL, 150/WDL and 150/NDL
10000
100
80
60
40
20
0
Survival rate in %
Hours burned
2000 3000 4000 5000 6000 8000 90007000
Luminous flux behaviour HQI-T 70/NDL, 150/WDL and 150/NDL
10000
100
80
60
40
20
0
Luminous flux in %
Hours burned
2000 3000 4000 5000 6000 7000 8000 9000